Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T.R. SMITH COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of T.R. SMITH COMPANY in 4722 47TH ST, WASHINGTON, DC 20016 (NAICS 236118). OSHA activity number 336324785.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T.R. Smith Company — free Get an email when a new federal OSHA severe-injury report for T.R. Smith Company is published. One employer, no account, unsubscribe in one click.
Establishment
T.R. SMITH COMPANY
Site address
4722 47TH ST
City
WASHINGTON
State
DC
ZIP
20016
Mailing
14401 DARNESTOWN RD, DARNESTOWN, MD 20874
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 2, 2013
Penalty
Initial $1,200 · Current $500 Reduced
29 CFR 1926.403(b)(2):      Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.    a) On or about August 22, 2012; second floor of building; a power strip/tap used to provide power to portable equipment such as but not limited to saws; either directly or through portable extension cords, was not designed for outdoor or construction.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii):     All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection.    a) On August 22, 2012; second floor, employees were operating electrical tools such as but not limited to skill saws which were not plugged into a ground fault circuit interrupter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 2, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.501(b)(13):     Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    a) On or about August 22, 2012; front roof area; employees conducting roof work on a 6 in 12 pitch roof were not protected by a personal fall arrest system to prevent them from falling 18-20 feet to ground level.    b) On or about August 22, 2012; second floor; wall openings were not guarded with a top rail to protect employees from falling 12 feet to ground level.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336324785.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.