Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WORTHINGTON CYLINDER CORPORATION

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of WORTHINGTON CYLINDER CORPORATION in 333 MAXTOWN ROAD, WESTERVILLE, OH 43082 (NAICS 331221). OSHA activity number 336341383.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Worthington Cylinder Corporation — free Get an email when a new federal OSHA severe-injury report for Worthington Cylinder Corporation is published. One employer, no account, unsubscribe in one click.
Site address
333 MAXTOWN ROAD
City
WESTERVILLE
State
OH
ZIP
43082
Mailing
333 MAXTOWN ROAD, WESTERVILLE, OH 43082
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
300
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 20, 2013
Abate by
Feb 13, 2014
Penalty
Initial $7,000 · Current $6,000 Reduced
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970:   The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees from a struck-by hazard of shifting or sliding steel coils:    a.  At the site, the employer stored 23 steel coils (weighing approximately 48,000 pound each) on steel rails stacked two high.  Two of the coils on the bottom row were not adequately chocked and blocked, thereby creating a hazard of shifting or sliding when coils would be moved.
Recent events (3)
  • — F (S) $6000
  • — C (S) $7000
  • — Z (S) $7000

View Worthington Cylinder Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336341383.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.