OSHA Inspection: PURCELL CONSTRUCTION CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PURCELL CONSTRUCTION CORPORATION in WARRIOR IN TRANSITION (WIT) BARRACKS PROJECT 500 STERNBERG AVENUE, FORT EUSTIS, VA 23604 (NAICS 236220). OSHA activity number 336343603.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Purcell Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Purcell Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
WARRIOR IN TRANSITION (WIT) BARRACKS PROJECT 500 STERNBERG AVENUE
City
FORT EUSTIS
State
VA
ZIP
23604
Mailing
1990 E. WHITEHILL ROAD SUITE B, PRINCE GEORGE, VA 23875
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
19
Ownership type
A

1 citation on file for this inspection.

1926.350 A10

Other-than-serious 1 instance 13 exposed
Issued
Oct 2, 2012
Penalty
Initial $3,400 · Current $2,040 Reduced
29 CFR 1926.350(a)(10):     Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a.)  Purcell Construction Company, WIT Barracks Project, Fort Eustis.  On or about September 13, 2012, one oxygen cylinder and one acetylene cylinder, in storage together for approximately four days, were not separated by a distance of twenty feet or by a barrier at least five feet high having a one-half hour fire rating.
Recent events (2)
  • — I (O) $2040
  • — Z (S) $3400