Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ECONOSWEEP & MAINTENANCE SERVICE, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ECONOSWEEP & MAINTENANCE SERVICE, INC. in 9501 ARLINGTON EXPRESSWAY SUITE 100, JACKSONVILLE, FL 32254 (NAICS 562998). OSHA activity number 336350780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Econosweep & Maintenance Service, INC. — free Get an email when a new federal OSHA severe-injury report for Econosweep & Maintenance Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9501 ARLINGTON EXPRESSWAY SUITE 100
City
JACKSONVILLE
State
FL
ZIP
32254
Mailing
P.O. BOX 6775, JACKSONVILLE, FL 32236
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562998
Employees
2
Ownership type
A

10 citations on file for this inspection.

1910.37 B02

Other-than-serious 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Feb 26, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":    a.  On or about September 14, 2012, inside the mechanic shop, the door that led from the mechanic shop to the outside did not have an "Exit" sign.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3600

1910.37 B05

Serious 3 instances 21 exposed
Issued
Feb 6, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $2,000
29 CFR 1910.37(b)(5):  Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):    a.  On or about September 14, 2011, inside the mechanic shop, the door that led from the mechanic shop to the storeroom did not have a "Not an Exit" sign.    b.  On or about September 14, 2011, inside the mechanic shop, the door that led from the mechanic shop to the foreman's office did not have a "Not an Exit" sign.    c.  On or about September 14, 2011, inside the mechanic shop, the door that led from the mechanic shop to the main office did not have a "Not an Exit" sign.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 6, 2013
Abate by
Mar 5, 2013
Penalty
Initial $6,300 · Current $5,000 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     a.  On or about September 14, 2012, an employee servicing a street sweeper did not attach a block device around the hydraulic cylinder prior to entering the danger point of the machine, exposing himself to a caught-in hazard.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $6300

1910.147 C07 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2013
Abate by
Mar 5, 2013
Penalty
Initial $4,500 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A):  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    a.  On or about September 14, 2012, the employer did not train employees how to recognize, isolate, and control energy sources associated with the operation of the street sweepers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4500

1910.219 D01

Serious Gravity 5 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Mar 5, 2013
Penalty
Initial $3,600 · Current $2,000 Reduced
29 CFR 1910.219(d)(1):  Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a.  On or about September 14, 2012, on the street sweeper trucks, the pulley that operates the vacuum and hydraulic system for the hopper did not have a guard, exposing employees to a nip point hazard.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3600

1910.219 E03 I

Serious Gravity 5 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Mar 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i):  Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):    a.  On or about September 14, 2012, on the street sweeper trucks, the belts that operated the vacuum and hydraulic system on the hopper did not have a guard, exposing employees to a moving belt.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Feb 12, 2013
Penalty
Initial $4,500 · Current $2,000 Reduced
29 CFR 1910.303(g)(2)(i):  Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a.  On or about September 14, 2012, in the south corner of the building, the two 5-horsepower air compressors did not have covers over live electrical parts, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4500

1910.305 B01

Serious Gravity 5 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Feb 12, 2013
Penalty
Initial $4,500 · Current $2,000 Reduced
29 CFR 1910.305(b)(1):  Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed:    a.  On or about September 14, 2012, in the mechanic shop, the main electrical panel was missing the knock out plugs, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4500

1910.1200 E01

Other-than-serious 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Mar 26, 2013
Penalty
Initial $3,600 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1):  The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a.  On or about September 14, 2012, the employer did not develop a written hazardous communication program for employees who work with chemicals such as but not limited to starter fluid, gasoline, diesel, and motor oil.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $3600

1910.1200 H01

Other-than-serious 1 instance 21 exposed
Issued
Feb 6, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):  The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area:    a.  On or about September 14, 2011, the employer did not provide training about hazardous communication and the hazards associated with chemicals such as but not limited to starter fluid, gasoline, diesel, and motor oil.