Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: POLLOCK READING, INCORPORATED

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of POLLOCK READING, INCORPORATED in 123 EAST HULLER LANE, READING, PA 19605 (NAICS 423930). OSHA activity number 336358783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pollock Reading, Incorporated — free Get an email when a new federal OSHA severe-injury report for Pollock Reading, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
123 EAST HULLER LANE
City
READING
State
PA
ZIP
19605
Mailing
P.O. BOX 759, POTTSTOWN, PA 19464
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
16
Ownership type
A

7 citations on file for this inspection.

1910.104 B08 VI

Serious Gravity 5 1 instance 16 exposed
Issued
Dec 5, 2012
Penalty
Initial $3,825 · Current $2,295 Reduced
29 CFR 1910.104(b)(8)(vi): Storage containers, piping, valves, regulating equipment, and other accessories were not protected against physical damage and against tampering:    (a)  Pollock Reading, Incorporated - The liquid oxygen storage tank located next to the Maintenance Shop was not protected against vehicle traffic, on or about September 14, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2295
  • — Z (S) $3825

1910.180 D04

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Dec 5, 2012
Abate by
Jan 2, 2013
Penalty
Initial $3,060 · Current $0 Reduced
29 CFR 1910.180(d)(4): The employer did not complete inspections of the crane at intervals as defined in paragraph (d)(2)(ii) of this section and to include the requirements of paragraph (d)(3) of this section:    (a)  Pollock Reading, Incorporated - The employer did not perform annual or more frequent inspections of the Terex Fochs MHL 350 truck cranes, on or about September 14, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3060

1910.180 D03 IV

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Dec 5, 2012
Abate by
Jan 2, 2013
Penalty
Initial $3,060 · Current $0 Reduced
29 CFR 1910.180(d)(3)(iv): The crane was not taken out of service when deterioration or leakage in air or hydraulic systems was noted:    (a)  Pollock Reading, Incorporated - The Terex Fochs MHL 350 crane equipped with a magnet for moving scrap was found to have a leaking hydraulic cylinder and was still in service, on or about September 25, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3060

1910.180 D04 X

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Dec 5, 2012
Abate by
Jan 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.180(d)(4)(x): The truck crane was not taken out of service when excessively worn or damaged tires were noted:    (a)  Pollock Reading, Incorporated - The Terex Fochs MHL 350 crane equipped with a magnet for moving scrap was found to have a piece of tire, approximately five inches by nine inches, missing and was still in service, on or about September 25, 2012.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A02 I

Other-than-serious 1 instance 3 exposed
Issued
Dec 5, 2012
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.215(a)(2)(i): Safety guards were not constucted to provide protection from the spindle end, nut, and outer flange:    (a)  Pollock Reading, Incorporated - The Skil pedistal grinder, Serial Number 68E, located in the warehouse was not equipped with a spindle end or nut guard, on or about September 14, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $2295
  • — Z (S) $2295

1910.215 B09

Other-than-serious 1 instance 3 exposed
Issued
Dec 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, were not constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel:    (a)  Pollock Reading, Incorporated - The Skil pedistal grinder, Serial Number 68E, located in the warehouse was not equipped with an adjustable tongue guard, on or about September 14, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01 II

Other-than-serious 1 instance 6 exposed
Issued
Dec 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): Working space required by this standard was used for storage:     (a)  Pollock Reading, Incorporated - The working space in front of the circuit breaker box in the warehouse was used for product storage, on or about September 14, 2012.    No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pollock Reading, Incorporated's full OSHA safety record →