Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BRADLEY'S ROOFING & HOME IMPROVEMENT INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BRADLEY'S ROOFING & HOME IMPROVEMENT INC. in 4 COLONIAL PLACE, PITTSBURGH, PA 15232 (NAICS 236118). OSHA activity number 336372792.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bradley'S Roofing & Home Improvement INC. — free Get an email when a new federal OSHA severe-injury report for Bradley'S Roofing & Home Improvement INC. is published. One employer, no account, unsubscribe in one click.
Site address
4 COLONIAL PLACE
City
PITTSBURGH
State
PA
ZIP
15232
Mailing
1315 4TH AVENUE, NEW BRIGHTON, PA 15066
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
7
Ownership type
A

7 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)      a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, employees were working on a scaffold platform that was not fully planked while installing fascia board onto the front of the residential house they were re-roofing.  The fall hazard was approximately 20 feet to the ground below.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(b)(10):  Scaffold components manufactured by different manufacturers were intermixed such that the components fit together with force and the scaffold's structural integrity was not maintained by the user:    (a) Jobsite at 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, a scaffold was used by employees to install fascia board. The scaffold platform was supported by a 24 foot aluminum ladder and fabricated frame stair tower which are not compatible components.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 14, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(e)(1):  When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, employees were not provided a safe means of access and egress to and from the stairtower scaffold and to the upper, main roof to perform roofing activities.  The distance from the scaffold platform to the roof was approximately 3 feet and the fall hazard was approximatley 20 feet to the ground below.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 14, 2013
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1926.451(f)(6):  Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):    a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, employees erected and dismantled a pumpjack scaffold approximately 3 feet from the 240 volt electric service power lines.  Employees engaged in the scaffold erection and dismantling were exposed to the hazard of electric shock.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 14, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.451(g)(1)(vii):  Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, a stairtower scaffold used by employees to access the roof was not equipped with guardrails and the employees that used this were not protected from falling by any other means.  The fall hazard to the employees was approximately 20 feet to the ground below.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1926.451 G02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 14, 2013
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1926.451(g)(2): The employer did not provide fall protection for employees erecting or dismantling supported scaffolds:    a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, an employee was in the process of moving a scaffold pick that he had been working from on a flat section of the roof on a two story residential dwelling.  The employee was protected from falling during the dismantling.  The employee fell approximately 23 feet to the ground below sustaining fatal injuries.    OR IN THE ALTERNATIVE    29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure:    a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, an employee was working from a flat section of roof on a two story residential dwelling was not protected from falling.  The employee was installing fascia board on the upper main roof.  The employee was exposed to a fall hazard of approximately 23 feet to the ground below.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7000

1910.1200 E01

Other-than-serious 7 instances 7 exposed
Issued
Mar 14, 2013
Abate by
Apr 2, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):  The employer did not develop, implement and maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g) and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met:    a) Jobsite, 4 Colonial Place, Pittsburgh, PA:  On or about September 17, 2012, the employer did not have a written hazardous communications program for the hazardous chemicals (i. e. Geocel 2300 roof sealant and Geocell 2321 gutter sealant) that the employees work with.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336372792.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.