Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EL MONSTROU DE LAS GOMAS USADAS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EL MONSTROU DE LAS GOMAS USADAS INC. in 1818 WEBSTER AVE, BRONX, NY 10457 (NAICS 441320). OSHA activity number 336378989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EL Monstrou DE LAS Gomas Usadas INC. — free Get an email when a new federal OSHA severe-injury report for EL Monstrou DE LAS Gomas Usadas INC. is published. One employer, no account, unsubscribe in one click.
Site address
1818 WEBSTER AVE
City
BRONX
State
NY
ZIP
10457
Mailing
1818 WEBSTER AVENUE, BRONX, NY 10457
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441320
Employees
6
Ownership type
A

13 citations on file for this inspection.

1910.37 A03

Serious Gravity 10 2 instances 10 exposed
Issued
Mar 7, 2013
Penalty
Initial $2,800 · Current $700 Reduced
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.    a) Job Site, West Area Side of Building:  An exit route leading from inside the building to Park Avenue, was locked with three sliding bolts and blocked with tires, on or about 9/12/2012.     b) Job Site, South Wall Area:  An exit route leading to an alleyway that lead to Webster Ave, was locked with a sliding bolt and a master lock and blocked with tire rims, boxes, rim machine, old lift machine and exercise machine, on or about 9/12/2012.
Recent events (3)
  • — F (S) $700
  • — C (S) $2800
  • — Z (S) $2800

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $2,000 · Current $400 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a) Job Site, North Wall:  Employees are exposed to unexpected energizing, startup or release of energy while cleaning the Femtec by Kafo machinery. A written energy control program was not established by the employer; or about 9/12/13.
Recent events (3)
  • — F (S) $400
  • — C (S) $2000
  • — Z (S) $2000

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.     a) Job Site, North Wall:  Employee(s) clean the Femtec By kafo Machinerey and were exposed to potentially hazardous energy.  No procedures were devloped to control potentially hazardous energy; on or about 9/12/13.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.    a) Job Site, North Wall:  Employee who cleans the " Femtec By Kafo Machinery", and exposed to potentailly hazardous energy, was not provided with lockout/tagout hardware; on or about 9/12/13.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $2,000 · Current $400 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a) Job Site, North Wall:  "Femtec By Kafo Machinery", Serial # 013348, Model # FV-40.  The safety interlock on the acces doors of the Femtac machine was malfunctioning allowing the ram to drill aluminum wheels to operate with the doors open exposing employee to the point of operation, on or about 9/12/12.
Recent events (3)
  • — F (S) $400
  • — C (S) $2000
  • — Z (S) $2000

1910.215 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.215(a)(2): Guard design. The safety guard shall cover the spindle end, nut, and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard, except:    a) Job site, North Wall:  "Central Machinery". The spindle end guards were not provided on a eight (8) inch Central bench grinder, on or about 9/14/2013.
Recent events (3)
  • — F (S) $400
  • — C (S) $1600
  • — Z (S) $1600

1910.215 A04

Serious 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.    a) Job Site, North Wall:  "Central 8"inch bench grinder". Work rest (s) was not provided on the bench grinder, on or about 9/14/12.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)    a) Job Site, South Wall:  "Central 8" inch bench grinder machine". An adjustable tongue was not installed on both sides of the bench grinder, on or about 9/12/2012.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $1,200 · Current $400 Reduced
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.    a) Job Site, North Wall Area:   "Kellogg American Compressor", Model Number B352A, Serial Number 5553559. The pulleys of the compressor approximately 45" above the floor were not guarded, on or about 9/12/2012.
Recent events (3)
  • — F (S) $400
  • — C (S) $1200
  • — Z (S) $1200

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.    a) Job Site, North Wall Area:  "Kellogg American Compressor", model # B352A, Seriak# 555359. Two belts were not guarded, on or about 9/12/2012.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    a) Job Site, Noth Wall:  Compressor air nozzle used to clean car breaks and the bottom of the cars, was dead end tested to read 75 p.s.i. , on or about 9/14/13.
Recent events (3)
  • — F (S) $400
  • — C (S) $1600
  • — Z (S) $1600

1910.303 G01

Serious Gravity 1 2 instances 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $1,200 · Current $400 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    a) Job Site, North Wall:   An electrical main panel of the Femtec machine, was obstructed by a 55 gallon drum, dog cage and a wood box, on or about 9/12/12.
Recent events (3)
  • — F (S) $400
  • — C (S) $1200
  • — Z (S) $1200

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 19, 2013
Penalty
Initial $1,200 · Current $400 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means:    a) Job Site, East Wall:  Live wires of an electrical panel were not provided with a cover, on or about 9/12/13.     b) Job Site, North Wall:  "Kellog American Compressor". Live wires were not provided with a cover over the compressor, on or about 9/12/12.
Recent events (3)
  • — F (S) $400
  • — C (S) $1200
  • — Z (S) $1200

View EL Monstrou DE LAS Gomas Usadas INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336378989.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.