Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LCI

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LCI in MAIN STREET AND SHEWELL AVE, DOYLESTOWN, PA 18901 (NAICS 237990). OSHA activity number 336386388.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LCI — free Get an email when a new federal OSHA severe-injury report for LCI is published. One employer, no account, unsubscribe in one click.
Establishment
LCI
Site address
MAIN STREET AND SHEWELL AVE
City
DOYLESTOWN
State
PA
ZIP
18901
Mailing
P.O. BOX 729, WATERFORD WORKS, NJ 08089
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.350 A09

Serious Gravity 1 2 instances 2 exposed
Issued
Oct 26, 2012
Penalty
Initial $1,517 · Current $1,517
29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times:    a) Main St. and Shewell Ave. - On or about September 17, 2012, an acetylene cylinder and oxygen cylinder where not secured into position for storage.
Recent events (1)
  • — Z (S) $1517

1926.350 A10

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a)  Main Street and Shewell Ave - On or about September 17, 2012, an oxygen cylinder and acetylene cylinder were placed next to each other while waiting to be removed from the site.
Recent events (1)
  • — Z (S) $0

View LCI's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336386388.