CHICAGO, IL —
OSHA Inspection: EDWARD JANUSZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDWARD JANUSZ in 1900 N NARRAGANSETT AVE, CHICAGO, IL 60639 (NAICS 238140). OSHA activity number 336393582.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDWARD JANUSZ
- Site address
- 1900 N NARRAGANSETT AVE
- City
- CHICAGO
- State
- IL
- ZIP
- 60639
- Mailing
- 220 LINDEN ROAD, NORTHBROOK, IL 60062
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 E01
- Issued
- Oct 2, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Employees were not provided with safe access to a ladder jack scaffold platform being used at an elevation of up to approximately 12.2 feet above the ground. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2800
1926.451 F03
- Issued
- Oct 2, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) The ladder jack scaffolds were not inspected by a competent person. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $2000
1926.1053 B16
- Issued
- Oct 2, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) Employees were exposed to a fall hazard when a portable ladder that was missing a foot was used for the construction of a ladder jack scaffold. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $0
1926.451 G01 I
- Issued
- Oct 2, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Employees were exposed to the hazard of falling while working from ladder jack scaffold platform elevated up to approximately 12.2 feet above the ground. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Oct 2, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) Ladders used by employees to gain access to the working surface did not have its side rails extended at least 3 feet above the surface. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2000
1926.300 B01
- Issued
- Oct 2, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Employees were using unguarded Bosch grinder while performing masonry tuckpointing work. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (O) $0
1926.405 G01 III C
- Issued
- Oct 2, 2012
- Abate by
- Oct 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
219 CFR 1926.405(g)(1)(iii)(C): Flexible cords were run through doorways, windows or similar openings: a) An extension cord was run through a broken window of a commercial building to power equipment for tuckpointing. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $0
More inspections at Edward Janusz
View Edward Janusz's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336393582.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.