Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIDWEST COOLING TOWER SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MIDWEST COOLING TOWER SERVICES, INC. in 8545 HWY 105, KROTZ SPRINGS, LA 70750 (NAICS 333415). OSHA activity number 336397583.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Midwest Cooling Tower Services, INC. — free Get an email when a new federal OSHA severe-injury report for Midwest Cooling Tower Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8545 HWY 105
City
KROTZ SPRINGS
State
LA
ZIP
70750
Mailing
8545 HWY 105, KROTZ SPRINGS, LA 70750
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
63
Ownership type
A

8 citations on file for this inspection.

1910.215 A04

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 7, 2013
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.215(a)(4):  Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.      On or about 18 September 2012, in the middle of the main work area, the employer allowed an employee to use a Sears No. 319211260 abrasive wheel grinder with an improperly adjusted work rest to sharpen a drill bit.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.215 B09

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)      On or about 18 September 2012, in the middle of the main work area, the employer allowed an employee to use a Sears No. 319211260 abrasive wheel grinder with an improperly adjusted tongue guard to sharpen a drill bit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 25, 2013
Penalty
Initial $2,625 · Current $1,575 Reduced
29 CFR 1910.305(b)(1)(ii):  Unused openings in cabinets, boxes, and fittings shall be effectively closed.      On or about 18 September 2012, in the middle of the main work area, the employer allowed an employee to be exposed to a breaker box with two missing knockouts.  Moreover, the door to the breaker box would not remain closed thereby increasing the likelihood of accidental contact with electrical current.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2625

1910.303 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):  Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.      On or about 18 September 2012, in the middle of the main work area, the employer allowed an employee to be exposed to a breaker box with unmarked breakers in which the purpose of each circuit is not evident.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 25, 2013
Penalty
Initial $1,575 · Current $0 Reduced
29 CFR 1910.303(b)(7)(iv):  There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.      On or about 18 September 2012, in the middle of the main work area, the employer allowed an employee to be exposed to electrical current due to a broken electrical plug on a Dayton drill press.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1575

1910.157 C01

Deleted Other-than-serious 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.      On or about 18 September 2012, the employer allowed an employee to leave an unidentified, unmounted portable fire extinguisher sitting on the end of the table saw bench.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Deleted Other-than-serious 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3):  The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.      On or about 18 September 2012, the employer allowed an employee to be exposed to a portable AMEREX ABC fire extinguisher (Model A411) without an annual inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Deleted Other-than-serious 1 instance 1 exposed
Issued
Mar 7, 2013
Abate by
Mar 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):  Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.      On or about 18 September 2012, along the north end of the shop, the employer allowed an employee to be exposed to a 200-amp Cutler-Hammer electrical panel to which access was impeded by materials stored on the floor.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Midwest Cooling Tower Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336397583.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.