VAN BUREN, AR —
OSHA Inspection: KITCHEN AND BATH IDEAS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KITCHEN AND BATH IDEAS, INC. in 3518 POINTER TRAIL EAST, VAN BUREN, AR 72957 (NAICS 337110). OSHA activity number 336404983.
Where did this inspection happen?
- Establishment
- KITCHEN AND BATH IDEAS, INC.
- Site address
- 3518 POINTER TRAIL EAST
- City
- VAN BUREN
- State
- AR
- ZIP
- 72957
- Mailing
- 3518 POINTER TRAIL EAST, VAN BUREN, AR 72957
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 8
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.107 B05 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media. On or about September 13, 2012 and times prior thereto, an employee of Kitchen and Bath Ideas, Inc. performed spray operations with the use of flammable chemicals such as but not limited to high build lacquer sealer, high build semi-gloss, and solid color oil stains in the spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. The ventilation system installed on the spray booth had an average air velocity of 15 feet per minute (fpm) over the open face of the booth, exposing employees to the potential for overexposure of chemicals and fire hazards.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.107 B10
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(10): When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination. On or about September 13, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed spray operations on wood cabinets with the use of chemicals such as but not limited to high build lacquer sealer, high build semi-gloss, and solid color oil stains in the spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. Light fixtures had been installed on the left, right, and top of the spray booth for illumination. The light fixtures did not have panels installed to effectively isolate the spraying area from the bulbs or to protect from flammable residue accumulation, exposing employees to fire hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.107 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: On or about September 13, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed spray operations on wood cabinets with flammable chemicals such as but not limited to high build lacquer sealer, high build semi-gloss, and solid color oil stains in the spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. The spray booth and work area inside of the paint shop surrounding the booth had an accumulation of flammable residue, exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Abate by
- Penalty
- Initial $2400.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Openings through which conductors enter boxes, cabinets, or fittings were not effectively closed. On or about October 4, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed spray operations on wood cabinets with flammable chemicals such as but not limited to high build lacquer sealer, high build semi-gloss, and solid color oil stains in a spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. A conductor was observed entering an opening behind a lighting fixture and the opening was not effectively closed, exposing employees to fire hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $2400
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about October 4, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed spray operations on cabinets and doors for the manufacture of kitchen and bath cabinets with the use of flammable chemicals in a spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. Extension cords were observed being used by the employer as a substitute for fixed wiring of the light fixtures, exposing employees to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about September 13, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed woodworking activities in the cabinet shop located at 3518 Pointer Trail East in Van Buren, Arkansas. An electrical outlet was observed without a cover on the wall where the water fountain was located, exposing employees to shock hazards.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.305 G01 IV B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors. On or about September 13, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed woodworking activities in the cabinet shop located at 3518 Pointer Trail East in Van Buren, Arkansas. A flexible cord was used for the connection of the installed water fountain and led to a power source. The flexible cord was observed running from the inside of the drywall through a hole and was connected to a motor installed on the outside wall.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: On or about September 13, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. performed spray operations with the voluntary use of half face air-purifying tight fitted respirators in the spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. A respirator previously used by an employee had been observed being stored on a work table and was not protected from damage, contamination, dust, or damaging chemicals and was not packed or stored to prevent deformation of the facepiece and exhalation valve.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: On or about September 13, 2012 and times prior thereto, employees of Kitchen and Bath Ideas, Inc. voluntarily used half face air-purifying tight fitted respirators with organic vapor cartridges while performing spray operations in the spray booth located at 3518 Pointer Trail East in Van Buren, Arkansas. The employer had not provided the information from mandatory Appendix D of 29 CFR 1910.134 in written or oral format to employees.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337110)
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
ORLANDO, FL—2026-07-15
ROSTOV, LLC
RICHMOND HILL, GA—2026-07-14
WILSON CABINETRY, LLC
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
More inspections in AR
SILOAM SPRINGS, AR—2026-07-15
CR CRAWFORD CONSTRUCTION LLC
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
BRINKLEY, AR—2026-07-14
ROGER WILKISON FARMS PARTNERSHIP
SEARCY, AR—2026-07-14
MASTER?S PLASTERING & MORE INC
LITTLE ROCK, AR—2026-07-09
NABHOLZ CONSTRUCTION CORPORATION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336404983.