OSHKOSH, WI —
OSHA Inspection: NEVAMAR LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEVAMAR LLC in 2750 VINLAND RD, OSHKOSH, WI 54901 (NAICS 337110). OSHA activity number 336413984.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEVAMAR LLC
- Site address
- 2750 VINLAND RD
- City
- OSHKOSH
- State
- WI
- ZIP
- 54901
- Mailing
- P.O. BOX 2248, OSHKOSH, WI 54901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 27
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C07 IV
- Issued
- Jan 25, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished: (a) On or about 9/11/2012, a temporary employee under supervision of the host company, was not trained and certified by the employer's lockout tagout program when the job description requires the use of lockout tagout. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.212 A01
- Issued
- Jan 25, 2013
- Abate by
- Mar 14, 2013
- Penalty
- Initial $2,975 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) The ingoing nip point between 4 inch conveyor belts and 8 inch wheels on the sanding machine were not guarded while employee fed material onto the conveyor. (b) The ingoing nip points between 4 inch conveyor belts and 8 inch wheels on the vinyl line were not guarded while employees caught and stacked product as it came off the line. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2975
1910.219 F03
- Issued
- Jan 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) A chain and sprocket on the drive motor of a panel flipper had the guard removed during operation. NO ABATEMENT CERTIFICATION OR DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Jan 25, 2013
- Abate by
- Feb 6, 2013
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) An adjustable tongue guard on a bench grinder was adjusted all the way up during operation, which is greater than one quarter of an inch. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.243 C04
- Issued
- Jan 25, 2013
- Abate by
- Feb 6, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.243(c)(4): The top half of the wheel of portable grinding machine(s) was not enclosed: (a) A portable Milwaukee hand grinder had the 180 degree guard removed during use. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02
- Issued
- Jan 25, 2013
- Penalty
- Initial $2,529 · Current $1,770 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) A junction box was missing a cover in the maintenance room. NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $1770.3
- — Z (S) $2529
1910.305 G01 III
- Issued
- Jan 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph: (a) A flexible cable was used for permanent wiring of a control panel on a printing machine. The cable was run from the electrical panel, up a wall, through rafters on the ceiling, and down to the control panel for the machine. (b) In building 8, an extension cord was run through a wall to the cold air storage room to power a dehumidifier. NO ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Nevamar LLC