BRONX, NY —
OSHA Inspection: CEC ELEVATOR CAB CORP.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CEC ELEVATOR CAB CORP. in 540 MANIDA STREET, BRONX, NY 10474 (NAICS 333921). OSHA activity number 336431382.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CEC ELEVATOR CAB CORP.
- Site address
- 540 MANIDA STREET
- City
- BRONX
- State
- NY
- ZIP
- 10474
- Mailing
- 540 MANIDA STREET, BRONX, NY 10474
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333921
- Employees
- 45
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 B01
- Issued
- Jan 14, 2013
- Penalty
- Initial $2,100 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route; Location: Stairs leading from the second floor to the street exit a) The employer did not ensure that sufficient lighting was present in the stairway; on or about September 18, 2012.
Recent events (2)
- — I (S) $1440
- — Z (S) $2100
1910.101 B
- Issued
- Jan 14, 2013
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: Location Loading Dock Bay a) Compressed gas cylinders were not secured to prevent them from tipping over; on or about September 18, 2012
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1910.107 E02
- Issued
- Jan 14, 2013
- Penalty
- Initial $2,800 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations exceeded minimum required for operations and ordinarily exceeded a supply for 1 day or one shift: Location: Spray Area Bench a) Serveral one-gallon conatiners of paint & paint-related products (Reducer, thinner) were found to be stored on the bench; on or about September 18, 2012.
Recent events (2)
- — I (S) $1500
- — Z (S) $2800
1910.107 E03
- Issued
- Jan 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(e)(3): Open or glass container(s) were used for bringing flammable or combustible liquids into spray finishing room(s): Location: Spray Area a) Open cantainers of class 1 flammables such as but not limited to MPC Reducer and enamels were present in the spray area; on or about September 18, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H01
- Issued
- Jan 14, 2013
- Abate by
- Mar 4, 2013
- Penalty
- Initial $2,100 · Current $1,440 Reduced
General-duty citation text
29 CFR 1910.134(h)(1): Respirators were not cleaned and disinfected using the procedures in Appendix B-2 of 29 CFR 1910.134 or equivalent procedures recommended by the respirator manufacturer: Location: Establishment a) Respirators were cleaned using only an alcohol based wipe; on or about September 18, 2012.
Recent events (2)
- — I (S) $1440
- — Z (S) $2100
1910.134 H02 I
- Issued
- Jan 14, 2013
- Abate by
- Mar 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:( Location: Establishment a) Respirators used by employees during welding and spray finishing operations were stored unprotected from contamination in the workplace; September 18, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Jan 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Location: At the foot of the stairs leading to the second floor from the work area A fire extinguisher was so mounted that the handle of the extinguisher was about seven feet above the ground; on or about September 18, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Jan 14, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(II): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals were not presnt on the container; Location: Spray Area a) Secondary containers used to store hazardous chemicals were not labeled to inform employees of the physical and health hazards of the hazardous chemical contained within; on or about September 18, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CEC Elevator CAB Corp.
View CEC Elevator CAB Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 333921)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336431382.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.