Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GRAND GLASS WINDOWS AND DOORS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAND GLASS WINDOWS AND DOORS, INC. in 638 ZEIGLER RD., MOBILE, AL 36608 (NAICS 321911). OSHA activity number 336451588.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grand Glass Windows and Doors, INC. — free Get an email when a new federal OSHA severe-injury report for Grand Glass Windows and Doors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
638 ZEIGLER RD.
City
MOBILE
State
AL
ZIP
36608
Mailing
638 ZEIGLER RD., MOBILE, AL 36608
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
28
Ownership type
A

5 citations on file for this inspection.

1910.252 A02 IX

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 22, 2012
Abate by
Oct 25, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.252(a)(2)(ix): Where cutting or welding was done near walls, partitions, ceiling or roof of combustible construction, fire-resistant shields or guards were not provided to prevent ignition:    (a) At the welder's station on the west side of the shop:  On September 20, 2012 and at times prior to; the employer failed to provide guards or fire resistant shielding to prevent ignition of a chipboard wall exposing employees to fire hazards such as burns and smoke and fume inhalation.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.252 A02 III A

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 22, 2012
Abate by
Oct 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(iii)(A): The employer did not provide fire watchers whenever welding or cutting was performed, where combustible materials were adjacent to the opposite side of metal partitions, walls, ceilings, or roofs and were likely to be ignited by conduction or radiation:    (a) At the west end of the shop:  On September 20, 2012 and at times prior to; the employer failed to provide fire watchers during welding operations where combustible material was within 35 feet, exposing employees to hazards associated with fires such as but not limited to burns and smoke and fume inhalation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Serious Gravity 1 1 instance 15 exposed
Issued
Oct 22, 2012
Abate by
Nov 5, 2012
Penalty
Initial $1,785 · Current $1,068 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    (a)  In the shop area along the south wall: On September 20, 2012 and at times prior to; the employer failed to adequately identify, mount or place fire extinguishers in a location that was readily accessible, exposing employees to hazards associated with fires.
Recent events (2)
  • — I (S) $1068
  • — Z (S) $1785

1910.157 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 22, 2012
Abate by
Nov 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:    (a)  In the shop area where fire extinguishers are provided:  On September 20, 2012 and at times prior to; the employer failed to provide training on the general principals of fire extinguisher use and the hazards involved with incipient stage fire fighting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 22, 2012
Abate by
Nov 5, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a)  In the welding shop:  On September 20, 2012 and at times prior to; the employer failed to provide adequate fixed wiring of a structure in that orange extension cords were used as fixed wiring to provide electrical service to the welding shop to operate grinders, chopsaws and other hand-held equipment, exposing employees to hazards associated with fires such as, but not limited to burns and smoke and fume inhalation.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336451588.