BELLWOOD, IL —
OSHA Inspection: RIDER DICKERSON, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIDER DICKERSON, INC. in 815 TWENTY-FIFTH AVE., BELLWOOD, IL 60104 (NAICS 323111). OSHA activity number 336452982.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIDER DICKERSON, INC.
- Site address
- 815 TWENTY-FIFTH AVE.
- City
- BELLWOOD
- State
- IL
- ZIP
- 60104
- Mailing
- 815 TWENTY-FIFTH AVE., BELLWOOD, IL 60104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 65
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Sep 26, 2012
- Abate by
- Oct 25, 2012
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): (a) Facility Wide - The procedure developed did not clearly and specifically outline the scope, authorization, rules and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance for equipment/machinary such as printing presses, stitchers, cutters, and HVAC. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.147 C06 I
- Issued
- Sep 26, 2012
- Abate by
- Oct 25, 2012
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: (a) Facility Wide - An annual or more frequent inspection of the energy control procedure was not completed to ensure the procedure was being followed and requirements of the standard were followed for machinery including but not limited to the printing presses, cutters, stitchers, and folding machines. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.178 L01 I
- Issued
- Sep 26, 2012
- Abate by
- Oct 25, 2012
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Shop Area - The employer did not ensure that each powered industrial truck operator was competent to operate the sit down powered industrial trucks and the motorized walk behind hand trucks safely as demonstrated by the successful completeon of trianing and evaluation. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.212 A01
- Issued
- Sep 26, 2012
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Press Room - The Miehle 60" printing press was in operation with the low ink roller unguarded. (b) Press Room - The Miehle 60" printing press had seven units with rotating shafts that were ungaurded. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.147 C07 IV
- Issued
- Sep 26, 2012
- Abate by
- Oct 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: (a) Facility Wide - The employer did not certify that each employee's training for the energy control procedures had been accomplished and kept up to date. In accordance with 29CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Rider Dickerson, INC.
View Rider Dickerson, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336452982.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.