SAN ANTONIO, TX —
OSHA Inspection: ALEJANDRO BEROIVIDES
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of ALEJANDRO BEROIVIDES in W. IH 10 & PRESIDIO PKWY, SAN ANTONIO, TX 78249 (NAICS 238130). OSHA activity number 336454384.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALEJANDRO BEROIVIDES
- Site address
- W. IH 10 & PRESIDIO PKWY
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78249
- Mailing
- 5317 LA JOLLA DR., GARLAND, TX 75043
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B01
- Issued
- Dec 7, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: On or about 9/16/12, employees were exposed to an electrical hazard from a damaged extension cord at the commercial building at West IH 10 & Presidio Pwky preforming roofing work.
Recent events (1)
- — Z (S) $1200
1926.501 B10
- Issued
- Dec 7, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: On or about 9/16/12, employees were exposed to a fall from height of approximately 20ft. while working at the edge of a low slope roof at the commercial building at West IH 10 & Presidio Pwky preforming roofing work.
Recent events (1)
- — Z (S) $2800
1926.501 B11
- Issued
- Dec 7, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: On or about 9/16/12, employees were exposed to a fall from height of approximately 25ft. while working at the edge of a steep slope roof at the commercial building at West IH 10 & Presidio Pwky preforming roofing work.
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- Dec 7, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.1053(b)(1): Where a portable ladder was used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder: On or about 9/16/12, employees were exposed to a fall from height of approximately 10 ft, while using a fiberglass A frame ladder to gain access to the roof of the commercial building with its rails not extended 3ft. above the landing at West IH 10 $ Presidio Pkwy.
Recent events (1)
- — Z (S) $2400
1926.1053 B04
- Issued
- Dec 7, 2012
- Abate by
- Dec 17, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: On or about 9/14/12, employees were exposed to a fall from height of approximately 10 ft, while using a fiberglass A frame ladder that was not full extended and braced to access the roof of the commercial building at the West IH 10 & Presidio Pwky while preforming roofing work.
Recent events (1)
- — Z (S) $1200
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336454384.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.