LAMPASAS, TX —
OSHA Inspection: DUBOSE PIPE & GATE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DUBOSE PIPE & GATE in 1047 N HWY 281, LAMPASAS, TX 76550 (NAICS 423510). OSHA activity number 336478987.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUBOSE PIPE & GATE
- Site address
- 1047 N HWY 281
- City
- LAMPASAS
- State
- TX
- ZIP
- 76550
- Mailing
- 1047 N HWY 281, LAMPASAS, TX 76550
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A05
- Issued
- Oct 11, 2012
- Abate by
- Oct 25, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: On or about September 9, 2012, three employees were conducting welding operations while using two industrial fans to cool the work area. The fans were located approximately three feet way and the blade covers had openings of approximately four inches, exposing the employee to the hazard of being struck by the rotating blades.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.303 G02 I
- Issued
- Oct 11, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about September 20, 2012, employees were accessing the breaker panel that provides 120 volt power to the work area without a cover in place to protect employees from live parts, exposing employees to the hazard of shock and/or electrocution.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.305 G02 II
- Issued
- Oct 11, 2012
- Abate by
- Oct 12, 2012
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: On or about September 20, 2012, employees were using a spliced 120v flexible cord to power the industrial fan, exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $600
- — Z (S) $1200