Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED URGENT CARE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ADVANCED URGENT CARE in 5058 CITY LINE AVENUE, PHILADELPHIA, PA 19131 (NAICS 621111). OSHA activity number 336495411.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Urgent Care — free Get an email when a new federal OSHA severe-injury report for Advanced Urgent Care is published. One employer, no account, unsubscribe in one click.
Site address
5058 CITY LINE AVENUE
City
PHILADELPHIA
State
PA
ZIP
19131
Mailing
5058 CITY LINE AVENUE, PHILADELPHIA, PA 19131
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
621111
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.1030 C01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $2,520 · Current $2,520

Hazardous substances 8400

29 CFR 1910.1030(c)(1)(i): Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure:    a. Medical and Dental Clinics  The employer did not establish a written Exposure Control Plan.  The Exposure Control Plan is a key provision of the standard because it requires the employer to identify the individuals who will receive the training, protective equipment, vaccination, and other provisions of this standard.  Observed On or About September 21, 2012
Recent events (1)
  • — Z (S) $2520

1910.1030 D02 I

Serious Gravity 5 3 instances 10 exposed
Issued
Nov 1, 2012
Abate by
Nov 16, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8400

29 CFR 1910.1030(d)(2)(i): Engineering and work practice controls were not used to eliminate or minimize employee exposure. Where occupational exposure remains after institution of these controls, personal protective equipment shall also be used.    a. Medical Side  An employee used EXEL International 5 ml Syringe and 22G x 1  inch Needle Combination (26219) to administer intramuscular injections of Cyanocobalmin (Vitamin B12), Solu Medrol, Gentamicin, and Ceftriaxone to patients. These needles were not equipped with built-in safety features designed either to eliminate or to minimize the risk of accidental percutaneous injuries from needles contaminated with bloodborne pathogens, such as, human immunodeficiency virus (HIV), hepatitis B (HBV), and hepatitis C (HCV).  Observed On or About September 21, 2012    b. Medical Side  An employee used Exel International 3 ml Syringe with 25G x 5/8 inch Needle Combination (26100) to administer intramuscular injections of Tetanus and Diphtheria Toxoids Adsorbed vaccines to patients. These needles were not equipped with built-in safety features designed either to eliminate or to minimize the risk of accidental percutaneous injuries from needles contaminated with bloodborne pathogens, such as, human immunodeficiency virus (HIV), hepatitis B (HBV), and hepatitis C (HCV).  Observed On or About September 21, 2012    c. Dental Side  The Dentists used Covidien Monoject 400 Plastic Hub Dental Needles 30G Short (8881400074) and Covidien Monoject 400 Plastic Hub Dental Needles 25G Long (8881400033) to administer Lidocaine, an anesthetic, to patients. These needles were not equipped with built-in safety features designed either to eliminate or to minimize the risk of accidental percutaneous injuries from needles contaminated with bloodborne pathogens, such as, human immunodeficiency virus (HIV), hepatitis B (HBV), and hepatitis C (HCV).  Observed On or About September 21, 2012
Recent events (1)
  • — Z (S) $0

1910.1030 D04 III B 1 I

Other-than-serious 1 instance 10 exposed
Issued
Nov 1, 2012
Abate by
Nov 2, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 8400

29 CFR 1910.1030(d)(4)(iii)(B)(1)(i): Regulated waste was placed in containers which were not closable:        a. Medical Clinic, Examination Room, Biohazard Trash Container - The employer did not place regulated waste, excluding contaminated sharps, in the appropriate container. Employees conducted medical procedures, such as, blood collection.  In the event of the container being tipped or upended, regulated waste can spill onto the floor.    There is a risk of accidental touching of objects.  Observed On or About September 21, 2012