WASHINGTON, DC —
OSHA Inspection: RENOVATION CONTRACTORS, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of RENOVATION CONTRACTORS, LLC in 1401 R STREET, NW, WASHINGTON, DC 20009 (NAICS 238910). OSHA activity number 336506993.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RENOVATION CONTRACTORS, LLC
- Site address
- 1401 R STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 8206 ANITA ROAD, PIKESVILLE, MD 21208
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.95 A
- Issued
- Nov 16, 2012
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: a) Exterior, Southside Main Entrance to Residential Lobby - A foreman was observed using a Stihl gasoline powered chop saw to cut into existing limestone and not wearing eye protection.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.451 B01 I
- Issued
- Nov 16, 2012
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a) Exterior, Southside Main Entrance to Residential Lobby - Laborer and foreman were observed standing on a scaffold work platform, 11 feet, 7 inches above the ground while cutting out a limestone window jamb, and the back of the work platform was 13 inches from the rear upright of the scaffold frame.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.451 E09 IV
- Issued
- Nov 16, 2012
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress. a) Exterior, Southside Main Entrance to Residential Lobby - A laborer was observed climbing on diagonal cross bracing while exiting a scaffold work platform and exposed to a fall of 11 feet, 7 inches to the ground below.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.451 G01
- Issued
- Nov 16, 2012
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Exterior, Southside Main Entrance to Residential Lobby - A foreman and laborer were observed on a scaffold work platform while cutting out an existing limestone window jamb, and exposed to an 11 feet, 7 inch fall hazard.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.452 C02
- Issued
- Nov 16, 2012
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: a) Exterior, Southside Main Entrance to residential Lobby - Employees were observed on a scaffold work platform, 11 feet, 7 inches above the ground, cutting out an existing limestone window jamb, and the upper scaffold frame was not provided a cross brace, which made the scaffold work platform unstable.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
More inspections at Renovation Contractors, LLC
View Renovation Contractors, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336506993.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.