Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WOODWARD DESIGN + BUILD, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WOODWARD DESIGN + BUILD, LLC in 150 BROADWAY ST., NEW ORLEANS, LA 70118 (NAICS 541330). OSHA activity number 336517792.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Woodward Design + Build, LLC — free Get an email when a new federal OSHA severe-injury report for Woodward Design + Build, LLC is published. One employer, no account, unsubscribe in one click.
Site address
150 BROADWAY ST.
City
NEW ORLEANS
State
LA
ZIP
70118
Mailing
1000 S. JEFFERSON DAVIS PKWY., NEW ORLEANS, LA 70125
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
250
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 III C

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2012
Abate by
Nov 26, 2012
Penalty
Initial $4,050 · Current $0 Reduced
29 CFR 1926.404(b)(1)(iii)(C):     Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.    a)	On or about September 20, 2012; at the center of the jobsite, employees were allowed to utilize an extension cord set to power a compound miter saw without visually inspecting the cord before each days use for defects.  The extension cord set was found to be missing a ground pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4050

1926.404 F06

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):     Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    a)	On or about September 20, 2012; at the center of the jobsite, employees were allowed to utilize an extension cord that was missing a ground pin.  The extension cord was used to power a compound miter saw used to cut PVC pipe.  The missing ground pin prevented the extension cord from having a continuous path to ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Woodward Design + Build, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336517792.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.