Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: META TEC OF ILLINOIS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of META TEC OF ILLINOIS, INC. in 125 N. COMMERCIAL STREET, LACON, IL 61540 (NAICS 331110). OSHA activity number 336524996.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meta TEC of Illinois, INC. — free Get an email when a new federal OSHA severe-injury report for Meta TEC of Illinois, INC. is published. One employer, no account, unsubscribe in one click.
Site address
125 N. COMMERCIAL STREET
City
LACON
State
IL
ZIP
61540
Mailing
125 N. COMMERCIAL STREET, LACON, IL 61540
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
45
Ownership type
A

4 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 13, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.22(a)(2):     The floors of every workroom were not maintained in a clean and, so far as possible, dry condition    Employees were exposed to slip hazards due to the accumulation of cutting fluids and oil mist on the the work platforms around the machines and the floors were not maintained in a clean and dry condition.
Recent events (1)
  • — Z (S) $1785

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 13, 2012
Penalty
Initial $2,975 · Current $2,975
29 CFR 1910.147(c)(4)(ii):     The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items of this section    Employees performing maintenance and servicing operations were exposed to the hazard of unexpected energization while working on machines and equipment and the employer had not developed machine-specific energy control procedures.
Recent events (1)
  • — Z (S) $2975

1910.147 C07 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 13, 2012
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i):     The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    Employees engage in the maintenance and servicing of machines and equipment were exposed to the hazard of expected energization and the employer had not provided adequate training for insolating machines and applying lockout devices.
Recent events (1)
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2012
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    Employees were exposed to hazards associated with powered industrial vehicles and the employer had not ensured that operators were evaluated at least once every 3 years.
Recent events (1)
  • — Z (S) $2380

View Meta TEC of Illinois, INC.'s full OSHA safety record →