CORAL SPRINGS, FL —
OSHA Inspection: VUTEC CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of VUTEC CORPORATION in 11711 WEST SAMPLE ROAD, CORAL SPRINGS, FL 33065 (NAICS 332999). OSHA activity number 336534987.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VUTEC CORPORATION
- Site address
- 11711 WEST SAMPLE ROAD
- City
- CORAL SPRINGS
- State
- FL
- ZIP
- 33065
- Mailing
- 11711 WEST SAMPLE ROAD, CORAL SPRINGS, FL 33065
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 100
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 P01
- Issued
- Nov 6, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition. As observed at the facility, on or about 8/30/2012, a propane powered Toyota forklift was operating while the single hold-down strap was not fastened.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.134 C01
- Issued
- Nov 6, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: As determined on or about 8-30-2012, the employer had not implemented a respiratory protection program at the facility for the employees who are required to wear 3M half-face respirators.
Recent events (1)
- — Z (O) $0
1910.1200 E01
- Issued
- Nov 6, 2012
- Abate by
- Dec 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: As determined on or about 8-30-2012, the employer has not developed, implemented, or maintained a written hazard communication program for chemicals used in the workplace such as, but not limited to: Nazdar Black, product code VF111,Nazdar Thinner, product code VF190; TCI powder coat, product name Bonded Chrome TGIC; Chemetall Oakite, product name CF-Rinse; Chemetall Oakite, product name CrysCoat 747 LTS.
Recent events (1)
- — Z (O) $0
More inspections at Vutec Corporation
View Vutec Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336534987.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.