POTTSTOWN, PA —
OSHA Inspection: DANA HOLDING CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DANA HOLDING CORPORATION in 1040 CENTER AVENUE, POTTSTOWN, PA 19464 (NAICS 336350). OSHA activity number 336535588.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANA HOLDING CORPORATION
- Site address
- 1040 CENTER AVENUE
- City
- POTTSTOWN
- State
- PA
- ZIP
- 19464
- Mailing
- 1040 CENTER AVENUE, POTTSTOWN, PA 19464
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336350
- Employees
- 270
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Dec 27, 2012
- Abate by
- Jan 12, 2013
- Penalty
- Initial $3,825 · Current $3,825
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Dana Holding Corporation - On or about September 24, 2012 the employer did not conduct an annual periodic inspection of the energy control procedures to include a review between the inspector and each authorized employee.
Recent events (2)
- — I (S) $3825
- — Z (S) $3825
1910.303 B01
- Issued
- Dec 27, 2012
- Penalty
- Initial $3,060 · Current $995 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Dana Holding Corporation Bracker Staker lift table. - On or about September 24, 2012 the outer protective coating of the flexible cord was damaged and exposing the inner wiring.
Recent events (2)
- — I (O) $994.5
- — Z (S) $3060
1910.305 G02 III
- Issued
- Dec 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Dana Holding Corporation Bracker Staker lift table. - On or about September 24, 2012 strain relief was not provided for the flexible cord connection of the pedal control entering into a small wiring trough box.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Dana Holding Corporation
View Dana Holding Corporation's full OSHA safety record →
More inspections in this industry (NAICS 336350)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336535588.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.