MOUNTAIN HOME, ID —
OSHA Inspection: NORTHWEST INTERIORS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NORTHWEST INTERIORS LLC in EDGEMEADE FACILITY, MOUNTAIN HOME, ID 83647 (NAICS 238140). OSHA activity number 336543384.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTHWEST INTERIORS LLC
- Site address
- EDGEMEADE FACILITY
- City
- MOUNTAIN HOME
- State
- ID
- ZIP
- 83647
- Mailing
- 3222 AIRPORT RD., NAMPA, ID 83687
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 C01 II
- Issued
- Nov 30, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $2,142 · Current $1,071 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet or less thereafter for scaffolds 3 feet wide or less, and every 26 feet or less thereafter for scaffolds greater than 3 feet wide. Such guys, ties and braces were not installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (measured from one end [not both] towards the other): a) East side scaffold: On September 20, 2012, and times prior thereto, employees were working on the top platform at a working height of approximately 31 feet on a 48 inch wide, 14 foot long, tubular welded frame scaffold that did not have a vertical tie at both ends of the scaffold at 16 feet in accordance with the 4:1 height requirement. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1071
- — Z (S) $2142
1926.451 G04 I
- Issued
- Nov 30, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $2,678 · Current $1,339 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) East side scaffold: On September 20, 2012, and times prior thereto, employees were working on a scaffold at a height of approximately 31 feet that did not have guard rails installed on the ends of the platform. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1339
- — Z (S) $2678
More inspections at Northwest Interiors LLC
View Northwest Interiors LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336543384.