PROVIDENCE, RI —
OSHA Inspection: JB CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JB CONSTRUCTION in 20 DE SOTO STREET, PROVIDENCE, RI 02909 (NAICS 236118). OSHA activity number 336545785.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JB CONSTRUCTION
- Site address
- 20 DE SOTO STREET
- City
- PROVIDENCE
- State
- RI
- ZIP
- 02909
- Mailing
- 166 EARLY STREET, 1ST FLOOR, PROVIDENCE, RI 02909
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.21 B02
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury(a) Jobsite: On or about 09/19/2012, employees were walking on construction debris with protruding nails, the hazards working within 10 feet of high voltage power lines, working at heights greater than six feet without fall protection, and the ladder was defective and not removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.25 A
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: Jobsite: On or about 09/19/2012 during the course of construction, alteration, or repairs, debris was not kept cleared from work areas, whereby employees were working in and around and walking on the construction debris.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.252 A
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s): On or about 09/19/2012, employees dropped roofing materials to the ground approximately 24 feet below without the use of an enclosed chute of wood, or equivalent material.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.416 A01
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about 09/19/2012, employees were performing construction activities in close proximity to the high voltage power line running parallel to the eave of the structure whereas neither individual where protected against electrical shock. The employees were within 10 feet of the power line whereby a contact incident occurred resulting in a fall.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.501 B13
- Issued
- Mar 1, 2013
- Abate by
- Mar 5, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Jobsite: On or about 09/19/2012 employees were performing construction activities on the roof of a two story residential structure whereby they were not protected by a guardrail system, net system, or personal fall protection exposing the employees to a fall of approximately 24 feet .
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.503 A01
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: Jobsite: Employees interviewed were not knowledgeable in recognition of fall hazards and the methods used to reduce the hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B15
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: Jobsite: On or about 09/19/2012, the Werner 32 extension ladder being used to bring materials up tho the second story had not been not inspected by a competent person for visible defects on a periodic basis whereby the ladder was missing one of the non-slip foot pads.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.1053 B16
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. Jobsite, Helme Street side: On or about 09/19/2012, the Werner 32 extension ladder was missing one of the non-slip foot pads and not immediatley removed from service and marked or tagged with "Do Not Use".
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Mar 1, 2013
- Abate by
- Mar 11, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about 09/19/2012, employees emplacing the Werner 32 foot extension ladder were exposed to electrical hazards whereby the ladder was set up approximately 12 inches from the live overhead power lines.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at JB Construction
View JB Construction's full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336545785.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.