Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAREONE AT EAST BRUNSWICK, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAREONE AT EAST BRUNSWICK, LLC. in 599 CRANBURY ROAD, EAST BRUNSWICK, NJ 08816 (NAICS 623110). OSHA activity number 336557988.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Careone at East Brunswick, LLC. — free Get an email when a new federal OSHA severe-injury report for Careone at East Brunswick, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
599 CRANBURY ROAD
City
EAST BRUNSWICK
State
NJ
ZIP
08816
Mailing
599 CRANBURY ROAD, EAST BRUNSWICK, NJ 08816
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
623110
Employees
220
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 15, 2012
Abate by
Mar 15, 2013
Penalty
Initial $2,295 · Current $2,295
29 CFR 1910.147(c)(4)(ii):  Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h):    a/ CareOne E. Brunswick, NJ Site Maintenance Area:  The lockout program provided did not include, but not limited to:   1/ the program was not documented and tailored to the site specific equipment to be worked on   2/ there were no specific steps documented to de-energize the equipment  3/ means to control the use and identity of locking devices  4/ designated personnel involved in the program, etc.    Equipment include: Industrial washers, dryers, HVAC system (air conditioners/heating units), etc.    Observed on or about 9/21/2012.
Recent events (3)
  • — R (S) $2295
  • — C (S) $2295
  • — Z (S) $2295

1910.335 A01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 15, 2012
Abate by
Nov 5, 2012
Penalty
Initial $3,060 · Current $0 Reduced
29 CFR 1910.335(a)(1)(i):  Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed:    a/ CareOne E. Brunswick, NJ Site  Maintenance Area:   Where employees are required (on a limited basis) to perform live electrical testing and/or trouble-shooting on machinery/equipment, protectors including but not limited to electrical rated gloves (minimum 250 to 500 volts), insulated tools, etc. were not provided for each electrical worker.  Site equipment voltage is 220.    Observed on or about 9/21/2012.
Recent events (3)
  • — R (S) $0
  • — C (S) $3060
  • — Z (S) $3060

1910.37 B05

Other-than-serious 4 instances 20 exposed
Issued
Oct 15, 2012
Abate by
Feb 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5):   Door(s) which were not an exit or way of exit access, and which were so located as to be likely to be mistaken for an exit, were neither identified by a sign reading "NOT AN EXIT" or similar designation nor identified by a sign indicating their actual character:    a/ CareOne/E. Brunswick, NJ Site  Throughout Facility - Including but not limited to Resident Hallways, Boiler Room, Dietary, etc.    1/ Doors that lead into adjacent rooms thar are not exits  2/ Doors that have small character marrkings that cannot be seen from a short distance  3/ Doors that have markings on the wall next to them that cannot be seen due to high storage  4/ Doors with the exit arrow pointing in the wrong direction    Observed on or about 9/21/2012.