Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: POLYMERA INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POLYMERA INC in 511 MILLIKEN DRIVE, HEBRON, OH 43025 (NAICS 325211). OSHA activity number 336560586.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Polymera INC — free Get an email when a new federal OSHA severe-injury report for Polymera INC is published. One employer, no account, unsubscribe in one click.
Establishment
POLYMERA INC
Site address
511 MILLIKEN DRIVE
City
HEBRON
State
OH
ZIP
43025
Mailing
511 MILLIKEN DRIVE, HEBRON, OH 43025
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
9
Ownership type
A

4 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 6, 2012
Abate by
Jan 3, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.101(b):     "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6.    Located on the outside of the facility at the loading dock area, there were two argon cylinders that were to be used in part for welding that were not secure, thereby exposing the employees to a struck-by hazard if a cylinder was to be knocked over.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $1700

1910.178 L01 II

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 6, 2012
Abate by
Jan 3, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.178(l)(1)(ii):     Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).    a.  At the facility, employees were required to move materials with a forklift without any forklift training, thereby exposing the employees to the hazards associated with forklift operation.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $1700

1910.303 B08 I

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 6, 2012
Abate by
Jan 3, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.303(b)(8)(i):     Electric equipment shall be firmly secured to the surface on which it is mounted.  Note to paragraph (b)(8)(i) of this section: Wooden plugs driven into holes in masonry, concrete, plaster, or similar materials are not considered secure means of fastening electric equipment.    a.  Located in the middle of the facility, along a building support column, there were three receptacle boxes connected together that were not secured to its surface, thereby exposing the employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $1700

1910.305 B02 I

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 6, 2012
Abate by
Jan 3, 2013
Penalty
Initial $1,700 · Current $1,190 Reduced
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    a.  At the workplace, there were exposed wires protruding from a junction box that was without a cover located on a wall near the loading dock, thereby exposing the employees to electrical shock hazards.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336560586.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.