Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAMPBELL'S SIDING & WINDOWS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAMPBELL'S SIDING & WINDOWS in 3743 W. TAYJAN, POST FALLS, ID 83854 (NAICS 238170). OSHA activity number 336576780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Campbell'S Siding & Windows — free Get an email when a new federal OSHA severe-injury report for Campbell'S Siding & Windows is published. One employer, no account, unsubscribe in one click.
Site address
3743 W. TAYJAN
City
POST FALLS
State
ID
ZIP
83854
Mailing
98 N BALTIC PLACE SUITE 101, MERIDIAN, ID 83642
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

11 citations on file for this inspection.

1926.304 I01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Mar 12, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.304(i)(1):     Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:    3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees were using a 10 inch Ryobi table saw, serial number XX093451698, model BTS16, to cut siding. The blade guards were removed. This condition exposed employees to amputation and struck by hazards.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation.    3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees assembled an aluminum Werner Pump Jack  and a  frame supported  scaffold without installing mud sills or on a stable surface.  The scaffolds were being utilized and employees were observed on the scaffold. This condition exposed employees to a fall hazard of up to 28 feet.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(3):     Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:    3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees assembled an aluminum Werner Pump Jack supported scaffold without ensuring the scaffold supports and planking were plumb as required by the manufacturer.  The scaffolds were being utilized and employees were observed on the scaffold. This condition exposed employees to a fall hazard of up to 28 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3):     Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.      3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees erected an aluminum Werner Pump Jack Scaffold without having the scaffold inspected for hazards by a competent person trained to recognize hazards associated with scaffolding. The scaffold was being utilized and employees were observed on the scaffold that was not equipped with guard rails, was not supported sufficiently, and did not have toeboards.  This condition exposed employees to a fall hazard of 28 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(7):     Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employees erected an aluminum Werner Pump Jack Scaffold without the supervision of a competent person.  The scaffold was being utilized and employees were observed on the scaffold that was not equipped with guard rails, was not supported sufficiently, and did not have toeboards.  This condition exposed employees to a fall hazard of 28 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.452(j)(2):     Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.    3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employee was observed working on a Pump Jack Scaffold approximately 28 feet above ground level. Scaffold was not secured at the bottom or any points in between to prevent swaying and displacement to maintain plumb. This condition exposed the employee to a fall hazard of 28 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1)(vii):     Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employee was observed working on a Pump Jack Scaffold approximately 28 feet above ground level. Scaffold did not have gaurdrails installed. This condition exposed the employee to a fall hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.454 A

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Mar 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):     The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.     3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, the employer did not ensure that each employee performing work on a scaffold was trained to recognize the hazards associated with the type of scaffold in use. This condition exposed employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 B

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Mar 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b):     The employer did not have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.     3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, the employer did not ensure that each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold was trained by a competent person to recognize any hazards associated with the work in question. This condition exposed employees to fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Feb 26, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.451(h)(1):     Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall.      3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, Employees erected an aluminum Werner Pump Jack Scaffold without the use of toeboards, netting or similar method to prevent objects from falling on employees working below. This condition exposed employees to a struck by hazard.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Feb 13, 2013
Abate by
Mar 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):     The path to ground from circuits, equipment, or enclosures was not permanent and continuous.      3743 W. Tayjan, Post Falls, ID 83854; on or about 26 September 2012 and times prior thereto, employer did not ensure that the path to ground from circuits, equipment, or enclosures was permanent and continuous. Two instances were observed. This condition exposed employees to an electrical shock hazard.            (a) A 10 inch, 120V 15A, Ryobi table saw, serial number XX093451698, model BTS16 was missing the ground plug.             (b) A 7  inch, 120V 13A Skilsaw Circular (Worm Drive) saw, serial number H4862, model HD77 was missing the ground plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Campbell'S Siding & Windows's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336576780.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.