Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GRANT CREEK EXCAVATING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GRANT CREEK EXCAVATING in N DAVIS STREET, MISSOULA, MT 59808 (NAICS 221320). OSHA activity number 336585195.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grant Creek Excavating — free Get an email when a new federal OSHA severe-injury report for Grant Creek Excavating is published. One employer, no account, unsubscribe in one click.
Site address
N DAVIS STREET
City
MISSOULA
State
MT
ZIP
59808
Mailing
316 EXPRESSWAY, MISSOULA, MT 59808
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221320
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,800 · Current $500 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    a) Construction Site; On or about September 17, 2012 and at times prior, employees were working in an excavation of approximately 8 feet deep with no training to enable recognition and abatement of cave in hazards.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2800

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,400 · Current $1,592 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:       a) Construction Site; On or about September 17, 2012 and at times prior, employees were working in an excavation of approximately 8 feet deep and were exposed to overhead struck by hazards.  The spoil pile containing large rocks was piled next to the excavation.
Recent events (2)
  • — I (S) $1592
  • — Z (S) $2400

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,800 · Current $1,592 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:     a) Construction Site; On or about September 17, 2012 and at times prior, the employer did not provide a means of egress for employees working in an excavation of approximately 8 feet deep.  The employees had to climb out the end of the trench approximately 100 feet away.
Recent events (2)
  • — I (S) $1592
  • — Z (S) $2800

1926.651 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,800 · Current $1,592 Reduced
29 CFR 1926.651(j)(2):     Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    a) Construction Site; On or about September 17, 2012 and at times prior, employees were exposed to overhead struck by hazards and cave in hazards while installing sewer line in an excavation with the spoil pile located next to the excavation.
Recent events (2)
  • — I (S) $1592
  • — Z (S) $2800

1926.651 K02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,800 · Current $1,592 Reduced
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s) was/were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety:       a) Construction Site; On or about September 17, 2012 and at times prior, employees were installing new sewer services in an excavation approximately 8 feet deep with vertical walls, of a type C soil, spoil pile location on the edge of the excavation and lacking cave in protection.
Recent events (2)
  • — I (S) $1592
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 18, 2012
Abate by
Jan 15, 2013
Penalty
Initial $2,800 · Current $1,592 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):     a) Construction Site; On or about September 17, 2012 and at times prior, employees were exposed to cave-in hazards while working in an excavation approximately 8 feet deep with no cave-in protection.
Recent events (2)
  • — I (S) $1592
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336585195.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.