ASHVILLE, OH —
OSHA Inspection: ASHVILLE GRAIN, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ASHVILLE GRAIN, LLC in 50 WEST MAIN STREET, ASHVILLE, OH 43103 (NAICS 424510). OSHA activity number 336588389.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASHVILLE GRAIN, LLC
- Site address
- 50 WEST MAIN STREET
- City
- ASHVILLE
- State
- OH
- ZIP
- 43103
- Mailing
- 50 WEST MAIN STREET, ASHVILLE, OH 43103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.272 J01
- Issued
- Nov 7, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $1,700 · Current $680 Reduced
General-duty citation text
29 CFR 1910.272(j)(1): The employer shall develop and implement a written housekeeping program that establishes the frequency and method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other exposed surfaces: a. At the workplace, the employer did not develop and implement a written housekeeping program that established the frequency and method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other exposed surfaces in areas including, but not limited to, the following: basement, dump/first floor, upper floors, back manlift area, and back manlift top floor.
Recent events (2)
- — I (S) $680
- — Z (S) $1700
1910.272 J02 II
- Issued
- Nov 7, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $1,700 · Current $680 Reduced
E101E200M104
General-duty citation text
29 CFR 1910.272(j)(2)(ii): The employer shall immediately remove any fugitive grain dust accumulations whenever they exceed 1/8 inch (.32 cm) at priority housekeeping areas, pursuant to the housekeeping program, or shall demonstrate and assure, through the development and implementation of the housekeeping program, that equivalent protection is provided: a. Inside the back manlift, fugitive grain dust accumulations of 1.75 to 4 inches which had covered the floor were not immediately removed. b. In the back manlift house on the top floor, fugitive grain dust accumulations of 0.25 to 1.5 inches which had covered surfaces such as the floor, top shelf of the cabinet, and bottom shelf of the cabinet were not immediately removed. c. In the back manlift area on the first floor, fugitive grain dust accumulations of 0.25 to 4 inches which had covered surfaces such as the floor, breaker box, individual breakers, conduit for the breaker box, horn, and conduit for the horn were not immediately removed. d. In the lower basement, fugitive grain dust accumulations of 0.134 to greater than 12 inches which had covered surfaces such as the floor, stairs, chute for small leg, boot for small leg, board laying across boot for small leg, chutes on East side of small leg, boot for big leg, boards on top of block structure, wall light, and receptacle for sump pump were not immediately removed.
Recent events (2)
- — I (S) $680
- — Z (S) $1700
1910.307 C
- Issued
- Nov 7, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $1,700 · Current $680 Reduced
E101E200M104
General-duty citation text
29 CFR 1910.307(c): Electrical installations. Equipment, wiring methods, and installations of equipment in hazardous (classified) locations shall be intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: a. In the back manlift house on the top floor, electrical equipment including, but not limited to, the duplex receptacle and extension cord plugged into the receptacle in a Class II, Division 1 location were not intrinsically safe, approved for a Class II, Division 1 location, or safe for a Class II, Division 1 location. b. In the back manlift area on the first floor, electrical equipment including, but not limited to, the circuit breaker box in a Class II, Division 1 location was not intrinsically safe, approved for a Class II, Division 1 location, or safe for a Class II, Division 1 location. c. In the lower basement, electrical equipment including, but not limited to, two wall mounted lights with no globes and a receptacle used to energize a sump pump in a Class II, Division 1 location were not intrinsically safe, approved for a Class II, Division 1 location, or safe for a Class II, Division 1 location.
Recent events (2)
- — I (S) $680
- — Z (S) $1700
1910.145 C02 I
- Issued
- Nov 7, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs shall be used only to warn against potential hazards or to caution against unsafe practices: a. At the entrance to the back manlift area on the first floor, the employer did not have a combustible dust hazard sign where explosive grain dust atmospheres may occur due to the handling of grain. b. At the entrance to the dump floor and basement, the employer did not have a combustible dust hazard sign where explosive grain dust atmospheres may occur due to the handling of grain. c. At the back entrance to the basement, the employer did not have a combustible dust hazard sign where explosive grain dust atmospheres may occur due to the handling of grain.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.272 M03
- Issued
- Nov 7, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.272(m)(3): A certification record shall be maintained of each inspection, performed in accordance with this paragraph (m), containing the date of the inspection, the name of the person who performed the inspection and the serial number, or other identifier, of the equipment specified in paragraph (m)(1)(i) of this section that was inspected: a. At the facility, the employer did not maintain certification records for inspections performed on equipment including, but not limited to, the following: four bucket elevators and the Myer continuous-flow bulk grain dryer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Nov 7, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met: a. At the facility, the employer did not have a written hazard communication program for employees who were exposed to hazardous chemicals such as propane, gasoline, bearing grease, 90 weight gear oil, 2-cycle oil, and aluminum phosphide.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Nov 7, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use: a. At the facility, the employer did not have a material safety data sheet (MSDS) or safety data sheet (SDS) for each hazardous chemical which employees used such as propane, gasoline, bearing grease, 90 weight gear oil, and 2-cycle oil.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Nov 7, 2012
- Abate by
- Dec 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets: a. At the facility, the employer did not provide hazard communication training for employees who were exposed to hazardous chemicals such as gasoline, bearing grease, 90 weight gear oil, 2-cycle oil, and aluminum phosphide.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ashville Grain, LLC
View Ashville Grain, LLC's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336588389.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.