WASHINGTON, DC —
OSHA Inspection: RKNY ELECTRIC CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RKNY ELECTRIC CONSTRUCTION in 4505 B ST SE, WASHINGTON, DC 20019 (NAICS 238210). OSHA activity number 336612783.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RKNY ELECTRIC CONSTRUCTION
- Site address
- 4505 B ST SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20019
- Mailing
- 6802 INDUSTRIAL DR UNIT 208, BELTSVILLE, MD 20705
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 20
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.404 B01 II
- Issued
- Oct 18, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters. On or about September 17, 2012; building 4505 D; employees using portable electrical tools such as but not limited to drills were plugged into outlets, directly or by extension cord, which the ground-fault circuit interrupter were improperly wired providing no protection to the operator.
Recent events (1)
- — Z (S) $1600