On , OSHA opened a planned safety inspection of THEATRICAL RESOURCES in 2001 E CAPITOL ST SE, WASHINGTON, DC 20003 (NAICS 711310). OSHA activity number 336613997.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THEATRICAL RESOURCES
- Site address
- 2001 E CAPITOL ST SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20003
- Mailing
- 15853 MONTE ST. UNIT 105, SYLMAR, CA 91342
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 711310
- Employees
- 70
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Dec 13, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. a) On or about July 17, 2012; throughout facility; employees were exposed to fall hazards of 12 or more feet while climbing the trusses platform during dismantling of the structures.
Recent events (1)
- · Z (S) $2800
1910.23 C02
- Issued
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(2): Every runway was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides 4 feet or more above floor or ground level. Wherever tools, machine parts, or materials are likely to be used on the runway, a toeboard shall also be provided on each exposed side. a) On or about July 17, 2012; sub-roof area; employees installing lights through the sub-roof area were accessing the area by walking up a runway platform which did not have railing to prevent the employees sliding down or maintaining on the path preventing them from side stepping and falling through the sub-floor.
Recent events (1)
- · Z (S) $0
1910.178 L04 III
- Issued
- Dec 13, 2012
- Abate by
- Feb 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. a) On or about July 17, 2012; throughout floor; employees operating powered industrial trucks at the facility have not been re-evaluated in seven years ensuring that they are operating the equipment safely and within the manufacturer's parameters.
Recent events (1)
- · Z (O) $0
More inspections at Theatrical Resources
View Theatrical Resources's full OSHA safety record →
More inspections in this industry (NAICS 711310)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 336613997.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.