Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: ATOMIQUEST LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATOMIQUEST LLC in 2001 E. CAPITOL ST SE, WASHINGTON, DC 20003 (NAICS 711310). OSHA activity number 336614391.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atomiquest LLC for free Get an email when a new federal OSHA severe-injury report for Atomiquest LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ATOMIQUEST LLC
Site address
2001 E. CAPITOL ST SE
City
WASHINGTON
State
DC
ZIP
20003
Mailing
10 WYNFIELD DR, LITITZ, PA 17543
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
711310
Employees
70
Ownership type
Private (A)

3 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 13, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.23(c)(1):     Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder.     a) On or about July 17, 2012; throughout facility; employees were exposed to fall hazards of 12 or more feet while climbing the trusses platform during dismantling of the structures.
Recent events (1)
  • · Z (S) $2800

1910.23 C02

Serious Gravity 5 6 instances 4 exposed
Issued
Dec 13, 2012
Abate by
Jan 10, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(2):     Every runway was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides 4 feet or more above floor or ground level.       a) On or about July 17, 2012; sub-roof area; employees installing lights through the sub-roof area were accessing the area by  walking up a runway which did not have railing to prevent the employees sliding down or maintaining on the path preventing them from side stepping and falling through the sub-floor.
Recent events (1)
  • · Z (S) $0

1910.178 L04 III

Other-than-serious 5 instances 5 exposed
Issued
Dec 13, 2012
Abate by
Feb 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii):     An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years.    a) On or about July 17, 2012; throughout floor; employees operating powered industrial trucks at the facility have not been re-evaluated in seven years to ensure that they are operating the equipment safely and within the manufacturer's parameters.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 336614391.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.