HUNTINGTON, WV —
OSHA Inspection: ARISTA SYSTEMS LLC DBA BPE CONSTRUCTION
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ARISTA SYSTEMS LLC DBA BPE CONSTRUCTION in 177 KINETIC DRIVE, HUNTINGTON, WV 25701 (NAICS 238140). OSHA activity number 336614797.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARISTA SYSTEMS LLC DBA BPE CONSTRUCTION
- Site address
- 177 KINETIC DRIVE
- City
- HUNTINGTON
- State
- WV
- ZIP
- 25701
- Mailing
- 5305 FALL CREEK ROAD, INDIANAPOLIS, IN 46220
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 L01 I
- Issued
- Jan 15, 2013
- Abate by
- Jan 23, 2013
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l), as referenced by the note contained in 1926.602(d): a. Four Story Hotel Under Construction: The operator of the JLG 10054 rough terrain forklift was not trained to operate this lift as evidence by the operator having a wooden pallet of masonry block up in the air approximately 30 feet and the load was bouncing up and down in an uncontrolled manner and the operator could not read the load rating chart as observed on 9-27-12. Abatement Certification Required for This Item
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.451 C02
- Issued
- Jan 15, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. Third Level South Side of Elevator Shaft: The 5 ft. wide by 7 ft. long by 5 ft. tall fabricated frame scaffold was not erected with base plates as observed on 9-27-12. Abatement Certification Required For This Item
Recent events (2)
- — I (S) $1200
- — Z (S) $1200
1926.451 F03
- Issued
- Jan 15, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. Adjacent to the Masonry Elevator Shaft: The 5 ft. wide by 7 ft. long by 5 ft. tall fabricated framed scaffold was not inspected by the competent person before each work shift or the base plates would have been identified as missing as determined on 9-27-12. Abatement Certification Required For This Item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Jan 15, 2013
- Abate by
- Jan 22, 2013
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a. Third Level South Side of Elevator Shaft: An employee used the cross brace of the 5 ft. wide by 7 ft. long by 5 ft. tall fabricated scaffold to climb down from the decked area of the scaffold to the floor as observed on 9-27-12. Abatement Certification Required For This Item
Recent events (2)
- — I (S) $1000
- — Z (S) $1200
More inspections in this industry (NAICS 238140)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336614797.