Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARISTA SYSTEMS LLC DBA BPE CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ARISTA SYSTEMS LLC DBA BPE CONSTRUCTION in 177 KINETIC DRIVE, HUNTINGTON, WV 25701 (NAICS 238140). OSHA activity number 336614797.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arista Systems LLC DBA BPE Construction — free Get an email when a new federal OSHA severe-injury report for Arista Systems LLC DBA BPE Construction is published. One employer, no account, unsubscribe in one click.
Site address
177 KINETIC DRIVE
City
HUNTINGTON
State
WV
ZIP
25701
Mailing
5305 FALL CREEK ROAD, INDIANAPOLIS, IN 46220
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.178 L01 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 23, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l), as referenced by the note contained in 1926.602(d):    a. Four Story Hotel Under Construction: The operator of the JLG 10054 rough terrain forklift was not trained to operate this lift as evidence by the operator having a wooden pallet of masonry block up in the air approximately 30 feet and the load was bouncing up and down in an uncontrolled manner and the operator could not read the load rating chart as observed on 9-27-12.    Abatement Certification Required for This Item
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.451 C02

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    a. Third Level South Side of Elevator Shaft: The 5 ft. wide by 7 ft. long by 5 ft. tall fabricated frame scaffold was not erected with base plates as observed on 9-27-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1200

1926.451 F03

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(3):     Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    a. Adjacent to the Masonry Elevator Shaft: The 5 ft. wide by 7 ft. long by 5 ft. tall fabricated framed scaffold was not inspected by the competent person before each work shift or the base plates would have been identified as missing as determined on 9-27-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 15, 2013
Abate by
Jan 22, 2013
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a. Third Level South Side of Elevator Shaft: An employee used the cross brace of the 5 ft. wide by 7 ft. long by 5 ft. tall fabricated scaffold to climb down from the decked area of the scaffold to the floor as observed on 9-27-12.    Abatement Certification Required For This Item
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1200

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336614797.