BREWSTER, NY —
OSHA Inspection: PUTNAM PRECISION PRODUCTS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PUTNAM PRECISION PRODUCTS INC in 3859 DANBURY ROAD, BREWSTER, NY 10509 (NAICS 326199). OSHA activity number 336618780.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PUTNAM PRECISION PRODUCTS INC
- Site address
- 3859 DANBURY ROAD
- City
- BREWSTER
- State
- NY
- ZIP
- 10509
- Mailing
- PO BOX 409, BREWSTER, NY 10509
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 400
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.37 A03
- Issued
- Dec 6, 2012
- Penalty
- Initial $3,400 · Current $2,720 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route was not kept free and unobstructed: a) SUV Turning Area, on or about 9/27/2012: The emergency exit access was obstructed by bags of tumbling media preventing employees from free access to the exit door.
Recent events (2)
- — I (S) $2720
- — Z (S) $3400
1910.305 A02 I
- Issued
- Dec 6, 2012
- Penalty
- Initial $2,168 · Current $1,084 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installations rated 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (A), (B) and (C) of this paragraph: a) Old Shipping Area, on or about 9/27/2012: the green extension cord was attached to the wall, over the doorway and into a power strip below a table used for weighing and shipping product.
Recent events (2)
- — I (S) $1084
- — Z (S) $2168
More inspections at Putnam Precision Products INC
View Putnam Precision Products INC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336618780.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.