Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DERINGER-NEY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DERINGER-NEY, INC. in 2 DOUGLAS STREET, BLOOMFIELD, CT 06002 (NAICS 335931). OSHA activity number 336624788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deringer-Ney, INC. — free Get an email when a new federal OSHA severe-injury report for Deringer-Ney, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DERINGER-NEY, INC.
Site address
2 DOUGLAS STREET
City
BLOOMFIELD
State
CT
ZIP
06002
Mailing
2 DOUGLAS STREET, BLOOMFIELD, CT 06002
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335931
Employees
142
Ownership type
A

2 citations on file for this inspection.

1910.217 C03 III F

Serious Gravity 10 1 instance 6 exposed
Issued
Nov 6, 2012
Abate by
Nov 13, 2012
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.217(c)(3)(iii)(f):   Mechanical power press(es) using presence sensing point of operation devices were not provided with guards to protect all areas of entry to the point of operation not protected by the presence sensing device(s):            The adjustable barrier guard on V & O 11-ton part-revolution power press #4 did not protect areas of entry to the point of operation on the right side of the press.  On or about September 25, 2012, an employee sustained an amputation injury while reaching around the light curtain, through an open adjustable barrier guard, into the point of operation.
Recent events (2)
  • — I (S) $3780
  • — Z (S) $6300

1910.217 E01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 6, 2012
Abate by
Dec 26, 2012
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.217(e)(1)(i):   A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment:        Production Floor:  At the time of the OSHA inspection on or about October 2, 2012, the employer had not established a monthly inspection schedule for the company's six V & O 11-ton part-revolution power presses.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

View Deringer-Ney, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336624788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.