Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAY REALTY GROUP, INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BAY REALTY GROUP, INC in 161 ENDICOTT, BOSTON, MA 02108 (NAICS 531190). OSHA activity number 336633987.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BAY Realty Group, INC — free Get an email when a new federal OSHA severe-injury report for BAY Realty Group, INC is published. One employer, no account, unsubscribe in one click.
Site address
161 ENDICOTT
City
BOSTON
State
MA
ZIP
02108
Mailing
879 BEACON STREET, BOSTON, MA 02115
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531190
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 4, 2013
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    Basement, 161 Endicott Street, Boston:  Workers were not informed of the hazards of carbon monoxide, a combustion product  and the avoidance and unsafe condition of using gasoline powered tools in a confned area.      On 9-28-12, during a drain pipe installation project, two workers were overexposed to carbon monoxide while cutting concrete flooring with a gasoline powered saw in a confined basement work area.  See Citation 1 item 3a for exposure information.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $2400

1926.34 C

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 4, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.    Basement 161 Endicott Street, Boston: Egress path to an exit door was partially blocked by stored material.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1200

1926.55 A

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 4, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.55(a): Employee(s) were exposed to material(s) at concentrations above those specified in the Threshold Limit Values of Airborne Contaminants for 1970 of the American Conference of Governmental Industrial Hygienists:    a) Basement, 161 Endicott Street, Boston: On 9-28-12,  a worker was exposed to 96.4 parts per million (ppm) of carbon monoxide calculated as an 8-hour time weighted average in excess of the Threshold Limit Value of 50 ppm, while cutting through concrete flooring with a gasoline powered saw.     b) Basement 161 Endicott Street, Boston: On 9-28-12, a worker was exposed to 128.7 parts per million(ppm) of carbon monoxide calculated as an 8 hour time weighted average in excess of the Threshold Limit Value of 50 ppm, while cutting through concrete flooring with a gasoline powered saw.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $2800

1926.55 B

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.55(b): Feasible administrative or engineering controls were not implemented to reduce employee exposure(s):    Basement 161 Endicott Street, Boston: On 9-28-12, administrative and/or engineering controls were not implemented to reduce airborne concentrations of carbon monoxide below the Threshold Limit value of 50 ppm, while workers were operating a gasoline powered saw to cut into concrete flooring.    Controls may include but are not limited to:     1. Use of local exhaust ventilation in the work space while equipment capable of emitting carbon monoxide was operated.     2. Install carbon monoxide detectors in the work space to ensure workers are warned when levels exceed 50 ppm.     3. Substitute gasoline with electrically powered equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336633987.