DELAWARE, OH —
OSHA Inspection: REDBUILT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REDBUILT, LLC in 200 COLOMET DRIVE, DELAWARE, OH 43015 (NAICS 321214). OSHA activity number 336642384.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REDBUILT, LLC
- Site address
- 200 COLOMET DRIVE
- City
- DELAWARE
- State
- OH
- ZIP
- 43015
- Mailing
- 200 COLOMET DRIVE, DELAWARE, OH 43015
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321214
- Employees
- 41
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 19, 2012
- Abate by
- Nov 18, 2012
- Penalty
- Initial $3,825 · Current $2,678 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc: a. On the double cord side of the building, the web clamp on the left side of the web splitter (S/N: E-152-11) was not guarded. b. On the double cord side of the building, the lower clamping mechanism which was covered with a clear soft plastic on the left side of the web splitter (S/N: E-152-11) was not properly guarded.
Recent events (2)
- — I (S) $2677.5
- — Z (S) $3825
1910.212 A03 II
- Issued
- Oct 19, 2012
- Abate by
- Nov 18, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle: a. On the double cord side of the building, the point of operation on the RK Machinery 160 ton hydraulic press was not properly guarded. b. On the LW side of the building, the point of operation on the cord cut-off saw at the end of the push-up machine was not properly guarded.