Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: I & OA SLUTSKY INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of I & OA SLUTSKY INC in WALKWAY OVER THE HUDSON 87 HAVILAND ROAD, HIGHLAND, NY 12528 (NAICS 238990). OSHA activity number 336651385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch I & OA Slutsky INC — free Get an email when a new federal OSHA severe-injury report for I & OA Slutsky INC is published. One employer, no account, unsubscribe in one click.
Establishment
I & OA SLUTSKY INC
Site address
WALKWAY OVER THE HUDSON 87 HAVILAND ROAD
City
HIGHLAND
State
NY
ZIP
12528
Mailing
PO BOX 396, HUNTER, NY 12442
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
27
Ownership type
A

7 citations on file for this inspection.

1910.134 E01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.134(e)(1):  The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace:    (a) On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers wearing North half-face respirator while torch cutting, drilling, and grinding metal.  The employees were not provided a medical evaluation prior to being required to wear the respirator.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.134 F02

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2):  The employer did not ensure that employees using tight fitting face piece respirators pass an appropriate qualitative or quantitative fit test prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter.    (a)  On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers wearing North half-face respirator while torch cutting, drilling, and grinding metal.  The employees were not fit tested, either qualitatively or quantitatively, prior to being required to use this respirator by the employer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.62 L01 III

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.62(l)(1)(iii): The employer did not provide the training program as initial training prior to the time of job assignment or prior to the start up date for this requirement:    (a) On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers wearing a North half-face respirator with particulate cartridges while torch cutting, grinding, and drilling steel.  The employer did not provide training for employees working with lead.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.1200 H

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h):    Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(1) and (2) on hazardous materials in their work area, at the time of their initial assignment and whenever a new hazard is introduced into their work area:    (a) On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers torch cutting, drilling, and grinding metal, containing chemicals such as, but not limited to, lead.  Employees were not informed or trained in the areas required by the Hazard Communication Standard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.62 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.62(c)(1): The employer did not ensure that no employees were exposed to lead at concentrations greater than fifty micrograms per cubic meter of air (50 ug/m3) averaged over an 8-hour period:    (a) On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers wearing North half-face respirator with P100 cartridges while torch cutting, drilling, and grinding metal.  The employer did not perform initial air monitoring to determine what measure to protect employees.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.62 D01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30ug/m3) calculated as an 8-hour time-weighted average (TWA):    (a) On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers wearing North half-face respirator with P100 cartridges while torch cutting, drilling, and grinding metal.  The employer did not perform initial air monitoring to determine what measure to protect employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.62 I05 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1926.62(i)(5)(i): The employer did not provide adequate handwashing facilities for use by employees exposed to lead in accordance with 29 CFR 1926.51(f):    (a) On or about 10/02/2012, and at times prior thereto, at bridge, for the ironworkers wearing North half-face respirator with P100 cartridges while torch cutting, drilling, and grinding metal.  The employer did not provide hand washing facilities to protect employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336651385.