Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BASS SIGNAL CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BASS SIGNAL CORPORATION in 251 INDUSTRIAL PARK, MILLEDGEVILLE, GA 31061 (NAICS 238990). OSHA activity number 336672183.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bass Signal Corporation — free Get an email when a new federal OSHA severe-injury report for Bass Signal Corporation is published. One employer, no account, unsubscribe in one click.
Site address
251 INDUSTRIAL PARK
City
MILLEDGEVILLE
State
GA
ZIP
31061
Mailing
251 INDUSTRIAL PARK, MILLEDGEVILLE, GA 31061
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
30
Ownership type
A

13 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $2,678 · Current $2,678
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA;  The cylinders were stored in the garage bay, just outside of the restroom, exposed to foot and vehicle traffic. The cylinders are used for daily welding and cutting operations.
Recent events (1)
  • — Z (S) $2678

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Dec 28, 2012
Penalty
Initial $4,410 · Current $4,410
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; the employer failed to develop specific procedures for the Ben Pearson Tubemaster, vehicle lift which has hydraulic, pneumatic, and gravity energy sources in which, employees are required to perform servicing and maintenance.
Recent events (1)
  • — Z (S) $4410

1910.147 C07 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Dec 28, 2012
Penalty
Initial $4,410 · Current $4,410
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees were exposed to potential struck-by and caught-in hazards while performing maintenance tasks on machinery that required lockout/tagout. The employer failed to ensure that the employees were trained in performing lockout/tagout.
Recent events (1)
  • — Z (S) $4410

1910.157 E02

Serious Gravity 5 1 instance 30 exposed
Issued
Nov 8, 2012
Abate by
Nov 21, 2012
Penalty
Initial $2,142 · Current $2,142
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; fire extinguishers had not been inspected on a monthly basis since 09/11/2012 where employees are required to fight incipient level fires.
Recent events (1)
  • — Z (S) $2142

1910.157 E03

Serious Gravity 5 1 instance 30 exposed
Issued
Nov 8, 2012
Abate by
Dec 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; portable fire extinguishers were not inspected annually since September, 2011. Employees are required to fight incipient level fires.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Nov 21, 2012
Penalty
Initial $2,142 · Current $2,142
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees were exposed to struck-by hazards where the drill press was not permanently affixed to the floor.
Recent events (1)
  • — Z (S) $2142

1910.215 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $1,821 · Current $1,821
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s)    On or about 10/02/2012 at 251 Industrial Park Drive Millidegeville, GA; employees were exposed to struck-by hazards where the bench grinder was missing the side guard covering the grinding wheel.
Recent events (1)
  • — Z (S) $1821

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees performing grinding operations were exposed to struck-by hazards where the work rest on the bench grinder was not installed.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees were exposed to struck-by hazards while performing grinding operations where the employer failed to ensure that the tongue guard was installed.
Recent events (1)
  • — Z (S) $0

1910.304 G05

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees were exposed to electrical hazards while performing grinding operations where the ground pin for the power cord was removed.
Recent events (1)
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Nov 21, 2012
Penalty
Initial $2,678 · Current $2,678
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees were using compressed air at greater than 100 P.S.I. to clean dirt from the floor.
Recent events (1)
  • — Z (S) $2678

1910.253 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $2,678 · Current $2,678
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:    On or about 10/02/2012 at 251 Industrial Park Drive Milledgeville, GA; employees were exposed to fire hazards where an oxygen cylinder was stored with acetylene cylinders.
Recent events (1)
  • — Z (S) $2678

1910.178 L04 III

Other-than-serious 1 instance 3 exposed
Issued
Nov 8, 2012
Abate by
Dec 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    On or about 10/02/2012 at 251 industrial Park Drive Milledgeville, GA; employees are exposed to struck-by hazards where the employer failed to evaluate the training of employees operating powered industrial trucks.
Recent events (1)
  • — Z (O) $0

View Bass Signal Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336672183.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.