OSHA Inspection: STEELE SOLUTIONS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of STEELE SOLUTIONS, INC. in 9909 S57TH STREET, FRANKLIN, WI 53132 (NAICS 332323). OSHA activity number 336677984.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Steele Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for Steele Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9909 S57TH STREET
City
FRANKLIN
State
WI
ZIP
53132
Mailing
9909 S57TH STREET, FRANKLIN, WI 53132
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
65
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 11, 2013
Abate by
Mar 21, 2013
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.147(c)(4)(ii)(B):     The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.    (a) The Lockout/Tagout program did not have machine specific procedures for shutting down and isolating the various stages of the paint line.  The paint line includes a three stage wash station, dryer, powder coating applicatiion, IR heating and curing ovens.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.147 C07 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 11, 2013
Abate by
Mar 21, 2013
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.147(c)(7)(i):     The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:    (a) Machine specific procedures and their associated training were not established for the automatic paint line.  The paint line consists of various stages including a three section parts cleaning and washing station, followed by a drying oven, powder paint application, IR  heating, curing and baking ovens.  Employees in contact with these different stages would include maintenance and the powder painters.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.134 E01

Other-than-serious 1 instance 3 exposed
Issued
Mar 11, 2013
Abate by
Mar 21, 2013
Penalty
Initial $500 · Current $350 Reduced
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) The powder painter using a half face painters respirator was not not provided a medical evaluation prior to it's usage.  The evaluation is to identify any possible problems associated with respirator usage such as asthma, allergies, or a heart condition.
Recent events (2)
  • — I (O) $350
  • — Z (O) $500

View Steele Solutions, INC.'s full OSHA safety record →