BRADENTON, FL —
OSHA Inspection: ANTHONY CRANE USA
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ANTHONY CRANE USA in 7700 CORTEZ RD., BRADENTON, FL 33782 (NAICS 238910). OSHA activity number 336695986.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANTHONY CRANE USA
- Site address
- 7700 CORTEZ RD.
- City
- BRADENTON
- State
- FL
- ZIP
- 33782
- Mailing
- 11410 58TH ST. N., PINELLAS PARK, FL 33782
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 16
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.180 D03 I
- Issued
- Nov 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $2,700 · Current $1,620 Reduced
General-duty citation text
29 CFR 1910.180(d)(3)(i): A daily inspection was not conducted of all control mechanisms for maladjustment interfering with proper operation: (a) At the site - daily inspections were not conducted of the control mechanisms such as but not limited to, brakes & clutches of the Grove TMS500E-225958 Crane, on or about October 3, 2012.
Recent events (2)
- — I (S) $1620
- — Z (S) $2700
1910.180 D03 II
- Issued
- Nov 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(3)(ii): A daily inspection was not conducted of all control mechanisms for excessive wear of components and contamination by lubricants or other foreign matter. (a) At the site - daily inspections were not conducted of the control mechanisms such as but not limited to, valves and cylinders of the Grove TMS500E-225958 Crane, on or about October 3, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.180 D03 IV
- Issued
- Nov 16, 2012
- Abate by
- Dec 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(3)(iv): A daily inspection was not conducted for deterioration or leakage in air or hydraulic systems: (a) At the site - daily inspections were not conducted of systems such as but not limited to, hydraulic system for leaks of the Grove TMS500E-225958 Crane on or about October 3, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238910)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336695986.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.