COLUMBUS, OH —
OSHA Inspection: PALMER DONAVIN
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PALMER DONAVIN in 1200 STEELWOOD RD, COLUMBUS, OH 43212 (NAICS 238220). OSHA activity number 336721600.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PALMER DONAVIN
- Site address
- 1200 STEELWOOD RD
- City
- COLUMBUS
- State
- OH
- ZIP
- 43212
- Mailing
- 1200 STEELWOOD RD, COLUMBUS, OH 43212
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 18
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $3,825 · Current $1,913 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees a. At the workplace, employees were operating a high lift order picker truck with a self retracting lifeline and a body belt to protect against a fall hazard. The body belt was not permitted to be used with a fall arrest system such as a self retracting lifeline due to the lack of fall arrest force distribution exposing employees to internal injury.
Recent events (2)
- — I (S) $1912.5
- — Z (S) $3825
1910.305 B01 II
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $3,825 · Current $1,913 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a. At the workplace, in the coil room, a junction box attached to the ventilation system had two approximately one inch openings exposing open wiring that were not effectively closed with a knockout plug. b. At the workplace, in the coil room, a receptacle box attached to the ventilation system junction box had an approximately one inch opening exposing open wiring that was not effectively closed with a knockout plug.
Recent events (2)
- — I (S) $1912.5
- — Z (S) $3825
1910.305 B02 I
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $3,825 · Current $1,913 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a. At the workplace, in aisle CO1A, there was an electrical outlet box mounted on a structural steel beam that did not have a faceplate installed to prevent employee exposure to contact with electrical current from exposed open wiring.
Recent events (2)
- — I (S) $1912.5
- — Z (S) $3825
1910.132 D02
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. a. At Palmer Donavin, located in Columbus, Ohio had employees that would use personal protective equipment to minimize hazards associated with their job tasks, but the employer had not performed a written hazardous assessment to certify which PPE should be worn while performing different tasks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury. a. At the workplace, at the East end of the main storage aisle, a portable fire extinguisher was not mounted. b. At the workplace, at the North East exit door of the building, a portable fire extinguisher was not mounted. c. At the workplace, at the North East battery charging station, a portable fire extinguisher was not mounted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G01
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting. a. At the workplace, the employer did not have a portable fire extinguisher educational program to ensure employees were trained in the proper use of portable fire extinguishers.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L06
- Issued
- Jan 24, 2013
- Abate by
- Mar 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. a. At the workplace, employer did not certify the training for employees who are authorized to operate the power industrial trucks.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238220)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336721600.