Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: ORRIOS CONSTRUCTIONS CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ORRIOS CONSTRUCTIONS CORP in 1400 SW 8TH ST., MIAMI, FL 33135 (NAICS 238140). OSHA activity number 336725205.

Watch Orrios Constructions Corp — free Get an email when a new federal OSHA severe-injury report for Orrios Constructions Corp is published. One employer, no account, unsubscribe in one click.
Site address
1400 SW 8TH ST.
City
MIAMI
State
FL
ZIP
33135
Mailing
10957 NW 63RD TERRACE, MIAMI, FL 33178
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    On or about 10-03-12, an employee was working on a scaffold that was not fully planked.
Recent events (1)
  • — Z (S) $1360

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:     On or about 10/03/12, an employee did not have a ladder to access the scaffold.
Recent events (1)
  • — Z (S) $1360

1926.451 F07

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    On or about 10-03-12, the prefrabricated frame scaffold was erected by an employee who was not supervised by a competetent person.
Recent events (1)
  • — Z (S) $1360

1926.452 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1360.00 · Current $1360.00
29 CFR 1926.452(c)(2):   Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    On or about 10-03-12, the prefrabricated frame scaffold did not have cross braces directly below where the employee was working.