GREENVILLE, DE —
OSHA Inspection: MID-ATLANTIC REALTY CO., INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of MID-ATLANTIC REALTY CO., INC. in 248 PRESIDENTIAL DRIVE, GREENVILLE, DE 19807 (NAICS 531311). OSHA activity number 336726187.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MID-ATLANTIC REALTY CO., INC.
- Site address
- 248 PRESIDENTIAL DRIVE
- City
- GREENVILLE
- State
- DE
- ZIP
- 19807
- Mailing
- 248 PRESIDENTIAL DRIVE, GREENVILLE, DE 19807
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 531311
- Employees
- 105
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 5, 2013
- Penalty
- Initial $7,000 · Current $6,532 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical, fire, and fall hazards as the employer did not ensure that inspections and tests were performed on a Holan 819 Aerial Device: a) Mid-Atlantic Realty Co., Inc., Greenville, DE - The employer did inspect and test a Holan 819 Aerial Device. On or about October 8, 2012.
Recent events (2)
- — I (S) $6532
- — Z (S) $7000
1910.67 C02 XI
- Issued
- Apr 5, 2013
- Penalty
- Initial $7,000 · Current $6,532 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(xi): The insulated portion of an aerial lift was altered, reducing its insulating value: a) Greenville Place Apartments, Greenville, DE - Alterations to a Holan 819 Aerial Device exposed employees to potential equipment failure, on or about October 8, 2012: 1. The lower boom's electrical insulating properties were reduced as the fiberglass insert between the lower boom's knuckle & turntable ends and the RTV sealed gaps connecting these ends were painted.
Recent events (2)
- — I (S) $6532
- — Z (S) $7000
1910.67 C02 II
- Issued
- Apr 5, 2013
- Penalty
- Initial $4,050 · Current $0 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(ii): Aerial lifts were not operated by trained persons: a) Greenville Place Apartments, Greenville, DE - An employee operating a Holan 819 Aerial Device was not trained. On or about October 8, 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $4050
1910.67 B02
- Issued
- Apr 5, 2013
- Penalty
- Initial $4,050 · Current $3,582 Reduced
General-duty citation text
29 CFR 1910.67(b)(2): A modified aerial lift was not certified by the manufacturer or NRTL as being at least as safe as the equipment was before modification: a) Greenville Place Apartments, Greenville, DE - Modifications to a Holan 819 Aerial Device exposed employees to potential equipment failure. On or about October 8, 2012. 1. Field attachable reusable fittings, used to repair damaged hydraulic hoses, were in use instead of fittings engineered for this particular device. 2. The lower boom's electrical insulating properties were modified as the fiberglass insert between the lower boom's knuckle & turntable ends, and the RTV sealed gaps connecting these ends were painted.
Recent events (2)
- — I (S) $3582
- — Z (S) $4050
1910.67 C02 IX
- Issued
- Apr 5, 2013
- Penalty
- Initial $4,050 · Current $3,582 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(ix): Controls were not plainly marked as to their function: a) Mid-Atlantic Realty Co., Inc., Greenville, DE - The rotation, upper boom, lower boom, & upper / lower boom selector controls, operated at the turntable, on a Holan 819 Aerial Device were not plainly marked so that control of the lift could be easily overridden in case of an emergency in which an employee in the bucket was unable to operate the controls operated at this platform. On or about October 8, 2012.
Recent events (2)
- — I (O) $3582
- — Z (S) $4050
1910.1200 E01
- Issued
- Apr 5, 2013
- Abate by
- Jun 17, 2013
- Penalty
- Initial $3,240 · Current $2,772 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in paragraphs (f), (g), & (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes items (i) and (ii) of this subparagraph: a) Mid-Atlantic Realty Co., Inc., Greenville, DE - Employees were exposed to hazards such as chemical and fire hazards, as the employer did not have a written program consisting of provisions for labeling, safety data sheets and information for employees using chemicals such as, but not limited to hydraulic oil and cleaning & plumbing chemicals. On or about October 9, 2012.
Recent events (2)
- — I (O) $2772
- — Z (S) $3240
1910.1200 H03 III
- Issued
- Apr 5, 2013
- Abate by
- Jun 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer has implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures, and personal protective equipment to be used: a) Mid-Atlantic Realty Co., Inc., Greenville, DE - Employees who were exposed to the hazards presented by chemicals such as, but not limited to, hydraulic fluid under pressure while used for the hydraulic system of a Holan 819 Aerial Device, were not trained on these hazards. On or about October 9, 2012.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.157 G02
- Issued
- Apr 5, 2013
- Abate by
- May 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Mid-Atlantic Realty Co., Inc., Greenville, DE - Employees who were expected to use portable fire extinguishers in the workplace were not trained. On or about October 8, 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mid-Atlantic Realty CO., INC.
View Mid-Atlantic Realty CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 531311)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336726187.