ELMIRA, NY —
OSHA Inspection: EASTERN METAL/USA-SIGN
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EASTERN METAL/USA-SIGN in 1430 SULLIVAN STREET, ELMIRA, NY 14901 (NAICS 339950). OSHA activity number 336749981.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EASTERN METAL/USA-SIGN
- Site address
- 1430 SULLIVAN STREET
- City
- ELMIRA
- State
- NY
- ZIP
- 14901
- Mailing
- 1430 SULLIVAN STREET, ELMIRA, NY 14901
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339950
- Employees
- 61
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 21, 2012
- Penalty
- Initial $2,800 · Current $1,550 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Fabrication, on or about 10/9/12: (2) Two Rockwell Delta drill presses were not provided with chuck guards. b) Fabrication, on or about 10/9/12: Charles Allen drill press was not provided with a chuck guards. c) Fabrication, on or about 10/9/12: Central Machinery drill press was not provided with a chuck guard.
Recent events (2)
- — I (S) $1550
- — Z (S) $2800
1910.212 A03 II
- Issued
- Nov 21, 2012
- Abate by
- Mar 1, 2013
- Penalty
- Initial $3,500 · Current $1,950 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Fabrication Department, on or about 10/9/12: Niagara Press Brake was not provided with point of operation guarding.
Recent events (2)
- — I (S) $1950
- — Z (S) $3500
1910.217 C02 I A
- Issued
- Nov 21, 2012
- Abate by
- Dec 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): a) Fabrication Department, on or about 10/9/12: Federal full revolution mechanical power press #4, barrier guard did not prevent the operator from reaching through and into the point of operation. b) Fabrication Department, on or about 10/9/12: Federal full revolution mechanical power Press #3, barrier guard did not prevent the operator from reaching through and into the point of operation. c) Fabrication Department, on or about 10/9/12: Bliss full revolution mechanical power Press #12, equipped with an A-gate type guard that did not prevent the operator from reaching through and into the point of operation. d) Fabrication Department, on or about 10/9/12: Walsh full revolution machanical power Press #5, barrier guard did not prevent the operator from reaching through and into the point of operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.36 D01
- Issued
- Nov 21, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) Signman Building, on or about 10/16/12: Exit door in the rear of the storage room had a metal bar across the middle of the door that prevented emergency egress from the area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Nov 21, 2012
- Abate by
- Dec 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Eastern Metal/USA-SIGN, on or about 10/16/12: The Employer did not conduct an inspection of their energy control procedures.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Eastern Metal/Usa-Sign
View Eastern Metal/Usa-Sign's full OSHA safety record →
More inspections in this industry (NAICS 339950)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336749981.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.