Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EASTERN METAL/USA-SIGN

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EASTERN METAL/USA-SIGN in 1430 SULLIVAN STREET, ELMIRA, NY 14901 (NAICS 339950). OSHA activity number 336749981.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eastern Metal/Usa-Sign — free Get an email when a new federal OSHA severe-injury report for Eastern Metal/Usa-Sign is published. One employer, no account, unsubscribe in one click.
Site address
1430 SULLIVAN STREET
City
ELMIRA
State
NY
ZIP
14901
Mailing
1430 SULLIVAN STREET, ELMIRA, NY 14901
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
61
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 3 exposed
Issued
Nov 21, 2012
Penalty
Initial $2,800 · Current $1,550 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a)  Fabrication, on or about 10/9/12:  (2) Two Rockwell Delta drill presses were not provided with chuck guards.    b)  Fabrication, on or about 10/9/12:  Charles Allen drill press was not provided with a chuck guards.    c)  Fabrication, on or about 10/9/12:  Central Machinery drill press was not provided with a chuck guard.
Recent events (2)
  • — I (S) $1550
  • — Z (S) $2800

1910.212 A03 II

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 21, 2012
Abate by
Mar 1, 2013
Penalty
Initial $3,500 · Current $1,950 Reduced
29 CFR 1910.212(a)(3)(ii):  Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):      a)  Fabrication Department, on or about 10/9/12:  Niagara Press Brake was not provided with point of operation guarding.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3500

1910.217 C02 I A

Serious Gravity 5 4 instances 3 exposed
Issued
Nov 21, 2012
Abate by
Dec 7, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(2)(i)(a):  Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):    a)  Fabrication Department, on or about 10/9/12:  Federal full revolution mechanical power press #4, barrier guard did not prevent the operator from reaching through and into the point of operation.     b)  Fabrication Department, on or about 10/9/12:  Federal full revolution mechanical power Press #3, barrier guard did not prevent the operator from reaching through and into the point of operation.      c)  Fabrication Department, on or about 10/9/12:  Bliss full revolution mechanical power Press #12, equipped with an A-gate type guard that did not prevent the operator from reaching through and into the point of operation.      d)  Fabrication Department, on or about 10/9/12:  Walsh full revolution machanical power Press #5, barrier guard did not prevent the operator from reaching through and into the point of operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 D01

Other-than-serious 1 instance 2 exposed
Issued
Nov 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1):  Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:      a)  Signman Building, on or about 10/16/12:  Exit door in the rear of the storage room had a metal bar across the middle of the door that prevented emergency egress from the area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 4 exposed
Issued
Nov 21, 2012
Abate by
Dec 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:      a)  Eastern Metal/USA-SIGN, on or about 10/16/12:  The Employer did not conduct an inspection of their energy control procedures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Eastern Metal/Usa-Sign's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336749981.