Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WIMAN CORPORATION in 1610 DESIGN WAY, DUPO, IL 62239 (NAICS 326112). OSHA activity number 336752787.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wiman Corporation — free Get an email when a new federal OSHA severe-injury report for Wiman Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
WIMAN CORPORATION
Site address
1610 DESIGN WAY
City
DUPO
State
IL
ZIP
62239
Mailing
1610 DESIGN WAY, DUPO, IL 62239
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
114
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2013
Penalty
Initial $3,600 · Current $2,000 Reduced
OSH ACT of 1970 Section (5)(a)(1):     The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees    Employees were exposed to burns while working on line 4A the Davis-Standard Thermatic Extruder that had the rupture tube capped not allowing for relief of excessive pressure.      Feasible means of abatement could have been achieved by following the Davis-Standard manual for Thermatic, Mark V & Vl and Fibermaster owners manual. This document was entitled, Davis-Standard manual for Thermatic, Mark V & Vl and Fibermaster, and it recommended the following:     Rupture disc must be installed before operating extruder.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3600

1910.132 D01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2013
Abate by
May 6, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:   Employees are exposed to burns while working on line D4A, Davis-Standard Thermatic Extruder.  The employer failed to conduct a hazard assessment when the rupture disc was replaced with a solid cap.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2013
Abate by
May 6, 2013
Penalty
Initial $3,600 · Current $1,900 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.      Employees working on line D4A are exposed to fire hazards; the electrical panel box next to the extruder was missing a cover plate on the front side.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3600

1910.305 B02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 9, 2013
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.      Instance 1:   Employees are exposed to fire hazards, the cover plate was missing on junction boxes on the southwest side of the upper platform next to line D4A.        Instance 2:    Employees are exposed to fire hazards, the cover plate was missing on the junction box between the hopper feed and the D4A extruder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.305 G01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2013
Abate by
May 6, 2013
Penalty
Initial $3,600 · Current $1,900 Reduced
29 CFR 1910.305(g)(1)(iii): If used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of this section, the flexible cord shall be equipped with an attachment plug and shall be energized from an approved receptacle outlet.      Employees working around the D4A extruder are exposed to electrical shock. Power cords being plugged into the die had damage to the flexible conduit exposing electrical wiring.