Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BROTHER'S AUTO REPAIR

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BROTHER'S AUTO REPAIR in 620 HUNTINGTON AVE, PROVIDENCE, RI 02907 (NAICS 238160). OSHA activity number 336759782.

Watch Brother'S Auto Repair — free Get an email when a new federal OSHA severe-injury report for Brother'S Auto Repair is published. One employer, no account, unsubscribe in one click.
Site address
620 HUNTINGTON AVE
City
PROVIDENCE
State
RI
ZIP
02907
Mailing
620 HUNTINGTON AVE, PROVIDENCE, RI 02907
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(10):     Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.  a) Jobsite: On or about 10-9-12 for a jobsite in Providence RI, employee's performing roofing work at the roof's edge, at a height of approximately 8 feet from the ground, were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system.
Recent events (1)
  • — Z (S) $2800

1926.503 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(2):     The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii):  (a) Jobsite: The employer did not assure that each employee working on the roof, and exposed to a fall of approximately 8 feet, was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii), for a jobsite located in Providence RI on or about 10-9-12.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336759782.