TACOMA, WA —
OSHA Inspection: ARMY RESERVE 88TH REGIONAL SUPPORT COMMAND
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ARMY RESERVE 88TH REGIONAL SUPPORT COMMAND in 401 EAST ALEXANDER AVE. PIER 23, TACOMA, WA 98421 (NAICS 336611). OSHA activity number 336762984.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY RESERVE 88TH REGIONAL SUPPORT COMMAND
- Site address
- 401 EAST ALEXANDER AVE. PIER 23
- City
- TACOMA
- State
- WA
- ZIP
- 98421
- Mailing
- 401 EAST ALEXANDER AVE. PIER 23, TACOMA, WA 98421
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 22
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.107 B05 IV
- Issued
- Jan 2, 2013
- Abate by
- Feb 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: (a) Spray booth did not have a fire surpression system installed.
Recent events (1)
- — Z (S) $0
1910.305 B02
- Issued
- Jan 2, 2013
- Abate by
- Feb 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) Second floor break room on north end of building outlet on wall opposite door was missing a cover.
Recent events (1)
- — Z (S) $0
1910.35
- Issued
- Jan 2, 2013
- Abate by
- Feb 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.35: Employer was not in compliance with the exit-route provisions of NFPA 101, Life Safety Code, 2009 edition, or the exit-route provisions of the International Fire Code, 2009 edition.(incorporated by reference, see section 1910.6). (a) Employer was using exit stairs for storage such as but not limited to paint, cleaning supplies and equipment
Recent events (1)
- — Z (O) $0
1910.37 B04
- Issued
- Jan 2, 2013
- Abate by
- Feb 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: (a) First floor south end of building exit sign is over door however when standing on the north end of hallway there is no sign to indicate there is an exit at the south end. (b) Second floor south end of building exit sign is over door however when standing on the north end of hallway there is no sign to indicate there is an exit at the south end. (c) Supply room on the first floor, when standing in any of the aisles there is no indication of where the exit is. One direction leads to exit other direction lead back into the building. (d) Mail room/Receiving area has five doors none are marked exit or not an exit, only one door leads to the exit.
Recent events (1)
- — Z (O) $0
1910.37 B05
- Issued
- Jan 2, 2013
- Abate by
- Feb 20, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): (a) Mail room/Receiving area has five doors none are marked exit or not an exit, only one door leads to the exit.
Recent events (1)
- — Z (O) $0
More inspections at Army Reserve 88TH Regional Support Command
View Army Reserve 88TH Regional Support Command's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336762984.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.