Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: 3M WAREHOUSE FREMONT, NE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of 3M WAREHOUSE FREMONT, NE in 515 S MAIN STREET, FREMONT, NE 68025 (NAICS 493110). OSHA activity number 336773205.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 3M Warehouse Fremont, NE — free Get an email when a new federal OSHA severe-injury report for 3M Warehouse Fremont, NE is published. One employer, no account, unsubscribe in one click.
Site address
515 S MAIN STREET
City
FREMONT
State
NE
ZIP
68025
Mailing
600 EAST MEIGS, VALLEY, NE 68064
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
40000
Ownership type
A

4 citations on file for this inspection.

1910.176 B

Other-than-serious 1 instance 3 exposed
Issued
Nov 16, 2012
Abate by
Dec 1, 2012
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.176(b):     Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.    Job site located at 515 S Main Street, Fremont, NE 68025-The employer had areas in the facility where material was stored on pallets in tiers that were not staked, blocked, interlocked and limited in height so that they were stable and secure against sliding or collapse causing injuries to employees.
Recent events (2)
  • — I (O) $3500
  • — Z (S) $7000

1910.303 G01 I B

Other-than-serious 1 instance 1 exposed
Issued
Nov 16, 2012
Abate by
Dec 1, 2012
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.303(g)(1)(i)(B):     The width of working space in front of the electric equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the working space shall permit at least a 90-degree opening of equipment doors or hinged panels; and    Job site located at 515 S Main Street, Fremont, NE 68025-The work space in front of an electrical panel operating at 600 volts, nominal, or less was less that the required 30 inches.  The work area was blocked with the storage of other material/equipment.
Recent events (2)
  • — I (O) $1700
  • — Z (S) $3400

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 16, 2012
Abate by
Dec 1, 2012
Penalty
Initial $4,250 · Current $2,125 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings were not effectively closed.    Job site located at 515 S Main Street, Fremont, NE 68025-The electrical panel designated Service Disconnect 1 of 3, service 3 located 350' South West had opening created by removing breakers that were not effectively closed after the breaker was removed.
Recent events (2)
  • — I (O) $2125
  • — Z (S) $4250

1910.22 D01

Other-than-serious 1 instance 1 exposed
Issued
Nov 16, 2012
Abate by
Dec 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1):     In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent.    Job site located at 515 S Main Street, Fremont, NE 68025-The upper storage area above the office area in the shipping and receiving area did not have the load limit for the area posted and securely affixed to the building area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336773205.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.