FREMONT, NE —
OSHA Inspection: 3M WAREHOUSE FREMONT, NE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 3M WAREHOUSE FREMONT, NE in 515 S MAIN STREET, FREMONT, NE 68025 (NAICS 493110). OSHA activity number 336773205.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3M WAREHOUSE FREMONT, NE
- Site address
- 515 S MAIN STREET
- City
- FREMONT
- State
- NE
- ZIP
- 68025
- Mailing
- 600 EAST MEIGS, VALLEY, NE 68064
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 40000
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.176 B
- Issued
- Nov 16, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.176(b): Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse. Job site located at 515 S Main Street, Fremont, NE 68025-The employer had areas in the facility where material was stored on pallets in tiers that were not staked, blocked, interlocked and limited in height so that they were stable and secure against sliding or collapse causing injuries to employees.
Recent events (2)
- — I (O) $3500
- — Z (S) $7000
1910.303 G01 I B
- Issued
- Nov 16, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $3,400 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): The width of working space in front of the electric equipment shall be the width of the equipment or 762 mm (30 in.), whichever is greater. In all cases, the working space shall permit at least a 90-degree opening of equipment doors or hinged panels; and Job site located at 515 S Main Street, Fremont, NE 68025-The work space in front of an electrical panel operating at 600 volts, nominal, or less was less that the required 30 inches. The work area was blocked with the storage of other material/equipment.
Recent events (2)
- — I (O) $1700
- — Z (S) $3400
1910.305 B01 II
- Issued
- Nov 16, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $4,250 · Current $2,125 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed. Job site located at 515 S Main Street, Fremont, NE 68025-The electrical panel designated Service Disconnect 1 of 3, service 3 located 350' South West had opening created by removing breakers that were not effectively closed after the breaker was removed.
Recent events (2)
- — I (O) $2125
- — Z (S) $4250
1910.22 D01
- Issued
- Nov 16, 2012
- Abate by
- Dec 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent. Job site located at 515 S Main Street, Fremont, NE 68025-The upper storage area above the office area in the shipping and receiving area did not have the load limit for the area posted and securely affixed to the building area.